Related Experiment Video
Updated: Apr 13, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Validation of a simple method for atrial fibrillation screening in patients with stroke
C Gandolfo1, M Balestrino, C Bruno
1Stroke Unit, Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics and Maternal-Infantile Health, University of Genoa, Largo Paolo Daneo, 3, 16132, Genoa, Italy, gandcaci@unige.it.
Insights
A low-cost device accurately detected atrial fibrillation (AF), a stroke risk factor, in acute stroke patients. This non-invasive technology shows high specificity and good sensitivity for AF detection in this population.
Area of Science:
- Cardiology
- Neurology
- Medical Technology
Background:
- Atrial fibrillation (AF) is a common cardiac arrhythmia and a significant stroke risk factor.
- Accurate AF detection is crucial for effective stroke prevention strategies.
- Existing diagnostic methods may have limitations in certain patient populations.
Purpose of the Study:
- To evaluate the reliability of a low-cost, non-invasive AFib device in detecting AF in patients experiencing acute stroke.
- To assess the diagnostic accuracy (sensitivity and specificity) of the AFib device compared to a 12-lead EKG.
Main Methods:
- An observational study was conducted on 207 acute stroke patients (mean age 77.7 years).
- Patients underwent testing with the AFib model BP3MQ1-2D device.
- Results were compared against a gold standard 12-lead EKG interpreted by a cardiologist.
Main Results:
- Atrial fibrillation was present in 18.4% of the study sample.
- The AFib device demonstrated a sensitivity of 0.895 and a specificity of 0.988.
- The overall accuracy of the device was 0.971, with high confidence intervals for both sensitivity and specificity.
Conclusions:
- The AFib device exhibits high specificity and good sensitivity for detecting AF in acute stroke patients.
- This non-invasive, low-cost technology is a potentially accurate tool for AF screening in this clinical setting.
- The findings support the consideration of this device for improving AF detection in stroke management.
Abstract:
Atrial fibrillation (AF) is the most common cardiac arrhythmia in adult and old people and represents a risk factor for stroke. Correct AF individuation bears strong relevance in primary and secondary stroke prevention. Our goal was to evaluate the reliability of a low-cost, non-invasive technology in detecting AF in acute stroke patients. AFib model BP3MQ1-2D (Microlife USA, Dunedin, FL) showed good accuracy in diagnosing AF in a general cardiologic outpatient population. We carried out an observational study in patients with recent stroke. We studied 207 subjects, 103 men, 104 women, mean age (±SD) 77.7 ± 11.34 years, who underwent a test by AFib device with indication of AF or lack of it. The golden standard was a 12-lead EKG done immediately and evaluated by a certified cardiologist. We computed estimates of Sensitivity and Specificity and their 95 % confidence intervals (CI). AF was present in 38 subjects from the sample of 207 (18.4 %). AFib correctly demonstrated AF in 34 and failed diagnosing AF in 4 cases; on the other hand, AFib correctly excluded AF in 167 and caused an erroneous diagnosis of AF in 2 cases. The Sensitivity was 0.895 (95 % CI 0.7597-0.958) and the Specificity was 0.988 (95 % CI 0.958-0.997). The AFib device global accuracy was 0.971 (95 % CI 0.938-0.987). This device was able to detect AF with high specificity and a good sensitivity. This device may be considered as an accurate tool in detecting AF in stroke patients.
More Related Videos
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias VI: Management of Dysrhythmias