Related Experiment Video
Updated: Apr 13, 2026

A Simple Non-invasive Method for Temporary Knockdown of Upper Limb Proprioception
Published on: March 3, 2018
Robot-aided assessment of wrist proprioception
Leonardo Cappello1, Naveen Elangovan2, Sara Contu3
1Department of Robotics Brain and Cognitive Sciences, Istituto Italiano di Tecnologia , Genova , Italy.
Introduction:
Impaired proprioception severely affects the control of gross and fine motor function. However, clinical assessment of proprioceptive deficits and its impact on motor function has been difficult to elucidate. Recent advances in haptic robotic interfaces designed for sensorimotor rehabilitation enabled the use of such devices for the assessment of proprioceptive function.
Purpose:
This study evaluated the feasibility of a wrist robot system to determine proprioceptive discrimination thresholds for two different DoFs of the wrist. Specifically, we sought to accomplish three aims: first, to establish data validity; second, to show that the system is sensitive to detect small differences in acuity; third, to establish test-retest reliability over repeated testing.
Methodology:
Eleven healthy adult subjects experienced two passive wrist movements and had to verbally indicate which movement had the larger amplitude. Based on a subject's response data, a psychometric function was fitted and the wrist acuity threshold was established at the 75% correct response level. A subset of five subjects repeated the experimentation three times (T1, T2, and T3) to determine the test-retest reliability.
Results:
Mean threshold for wrist flexion was 2.15°± 0.43° and 1.52°± 0.36° for abduction. Encoder resolutions were 0.0075°(flexion-extension) and 0.0032°(abduction-adduction). Motor resolutions were 0.2°(flexion-extension) and 0.3°(abduction-adduction). Reliability coefficients were r T2-T1 = 0.986 and r T3-T2 = 0.971.
Conclusion:
We currently lack established norm data on the proprioceptive acuity of the wrist to establish direct validity. However, the magnitude of our reported thresholds is physiological, plausible, and well in line with available threshold data obtained at the elbow joint. Moreover, system has high resolution and is sensitive enough to detect small differences in acuity. Finally, the system produces reliable data over repeated testing.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...