Related Experiment Video
Updated: Apr 13, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Tuning aerosol performance using the multibreath Orbital® dry powder inhaler device: controlling delivery parameters
Bing Zhu1, Paul M Young1,2, Hui Xin Ong1,2
1Respiratory Technology, Woolcock Institute of Medical Research, Glebe, New South Wales, 2037, Australia.
Abstract:
The current study presents a new approach to tackle high-dose lung delivery using a prototype multibreath Orbital® dry powder inhaler (DPI). One of the key device components is the "puck" (aerosol sample chamber) with precision-engineered outlet orifice(s) that control the dosing rate. The influence of puck orifice geometry and number of orifices on the performance of mannitol aerosols were studied. Pucks with different orifice configurations were filled with 400 mg of spray-dried mannitol and tested in the Orbital® DPI prototype. The emitted dose and overall aerodynamic performance across a number of "breaths" were studied using a multistage liquid impinger. The aerosol performances of the individual actuations were investigated using in-line laser diffraction. The emptying rate of all pucks was linear between 20% and 80% cumulative drug released (R(2) > 0.98), and the amount of formulation released per breath could be controlled such that the device was empty after 2 to 11 breath maneuvers. The puck-emptying rate linearly related to the orifice hole length (R(2) > 0.95). Mass median aerodynamic diameters of the emitted aerosol ranged from 4.03 to 4.62 μm and fine particle fraction (≤6.4 μm) were 50%-66%. Laser diffraction suggested that the aerosol performance and emptying rates were not dependent on breath number, showing consistent size distribution profiles.
Related Concept Videos
Inhaled Medications
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
COPD: Management Using Bronchodilators and Corticosteroids
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:

