Detection of pulmonary metastases with the novel radiolabeled molecular probe, (99m)Tc-RRL
Related Experiment Video
Updated: Apr 13, 2026

Evaluation of Lung Metastasis in Mouse Mammary Tumor Models by Quantitative Real-time PCR
Published on: January 29, 2016
Ning Yao1, Ping Yan1, Rong-Fu Wang1
1Department of Nuclear Medicine, Peking University First Hospital West District, Beijing 100034, China.
Background:
To improve the detection of pulmonary metastases, experimental blood-borne pulmonary metastasis mouse models were established using three intravenously administered cell lines. In a previous study we demonstrated that (99m)Tc-radiolabeled arginine-arginine-leucine (RRL) could be used to non-invasively image malignant tumors.
Methods:
(99m)Tc-RRL was prepared and injected intravenously in mice with pulmonary metastases that arose from the intravenous injection of HepG2, B16, and Hela cells. The bio-distribution and imaging of (99m)Tc-RRL were determined in different pulmonary metastases mouse models and in normal mice.
Results:
(99m)Tc-RRL exhibited higher uptake values in the lungs of pulmonary metastatic mice compared to normal mice (P<0.05; 3.92±0.48% ID/g 2 h post-injection and 3.89±0.36% ID/g 4 h post-injection in metastatic hepatic carcinoma [HepG2]-bearing lungs; 5.49±0.84% ID/g 2 h post-injection and 5.11±0.75% ID/g 4 h post-injection in metastatic melanoma [B16]-bearing lungs; 3.72±0.52% ID/g 2 h post-injection and 3.51±0.35% ID/g 4 h post-injection in metastatic cervical carcinoma [Hela]-bearing lungs; 2.38±0.20% ID/g 2 h post-injection and 2.11±0.24% ID/g 4 h post-injection in normal lungs). The pulmonary metastatic lesions were clearly visualized using (99m)Tc-RRL.
Conclusions:
(99m)Tc-RRL exhibited favorable metastatic tumor targeting and imaging properties, thus highlighting its potential as an effective imaging probe for detection of pulmonary metastases. (99m)Tc-RRL can be used as a reasonable supplement to (18)F-FDG imaging in the non-invasive imaging of tumor angiogenesis.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

