Related Experiment Video
Updated: Apr 13, 2026

On-Site Sampling and Extraction of Brain Tumors for Metabolomics and Lipidomics Analysis
Published on: May 31, 2020
In vitro detection of small molecule metabolites excreted from cancer cells using a Tenax TA thin-film
Takuma Nozoe1, Shigemi Goda1, Roman Selyanchyn2
1Graduate School of Environmental Engineering, The University of Kitakyushu, 1-1 Hibikino, Wakamatsu, Kitakyushu 808-0135, Japan.
Abstract:
We developed a new device for the in vitro extraction of small molecule metabolites excreted from cancer cells. The extraction device, which was biocompatible and incubated with cancer cells, consists of a thin Tenax TA film deposited on the surface of a cylindrical aluminum rod. The Tenax TA solid phase was utilized for the direct extraction and preconcentration of the small molecule metabolites from a cell culture sample. The device fabrication and the metabolite extraction were optimized, tested, and validated using HeLa cell cultures. Comparison of metabolic profiles with the control measurement from the culture medium enabled detection of metabolites that were consumed or produced by the cell culture. Tentative identification and semi-quantitative investigation of the excreted metabolites were performed by GC-MS analysis. The proposed approach can be a valuable tool for the characterization of low-volatile cancer cell metabolites that are not covered by use of conventional methods based on headspace solid phase microextraction.