Related Experiment Video
Updated: Apr 13, 2026

Combined Supine and Standing Imaging for Varicocele: An Improved Diagnostic Approach
Published on: November 22, 2024
Prospective evaluation of a protocol for using transabdominal ultrasound to screen for short cervix
Santosh Pandipati1, C Andrew Combs1, Alan Fishman1
1Obstetrix Medical Group, San Jose, CA.
Objective:
We sought to evaluate a recently proposed protocol whereby transabdominal ultrasound of the cervix might be used as a prescreen to select women to undergo or to forgo measurement of cervical length via transvaginal ultrasound (CLvag).
Study Design:
This was a prospective cohort study. Measurements of cervical length via transabdominal ultrasound (CLabd) and CLvag were made in women with singleton pregnancy during routine obstetrical ultrasound examination at 18(0/7) to 23(6/7) weeks of gestation. The transabdominal screen was considered positive if CLabd was ≤36 mm with the maternal bladder full or ≤35 mm with the bladder empty, or adequate imaging of the cervix could not be obtained. Sensitivity, specificity, predictive values, and likelihood ratios of a positive screen to detect a short cervix (CLvag ≤25 mm) were calculated.
Results:
An interim analysis identified several technical problems with CLabd measurements, so the protocol was extensively revised. Under the revised protocol, 1580 women were included. Adequate views of the cervix were obtained via transabdominal imaging in 46% of subjects with the bladder empty and 56% with the bladder full. The correlation between CLabd and CLvag was poor (r = 0.38). Of the 17 patients with a short cervix, 15 had suboptimal transabdominal exams (screen positive) and 2 had CLabd ≤35 mm with bladder empty (screen positive). Sensitivity of the screen was 100% (95% confidence interval, 80.5-100%) but specificity was only 32.2% (95% confidence interval, 29.9-34.6%) and screen positive rate was 66.3%. Several technical problems and limitations of transabdominal imaging of the cervix are shown.
Conclusion:
Using modern, high-resolution ultrasound equipment, we were unable to adequately image the cervix via transabdominal ultrasound in half the cases. Although we confirmed that a CLabd cutoff value of 35-36 mm is appropriate for detection of short cervix, the technique for measuring CLabd is fraught with technical problems. Practitioners must validate the technique in their own practice before adopting this or similar prescreening protocols. We decided not to adopt this protocol.
More Related Videos
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...

