Background:
Home blood pressure (BP) measurement (HBPM) is recommended for the diagnosis and follow-up of high BP. It is unclear how this aspect of BP monitoring has evolved over the years and whether interventions could influence patient adherence to HBPM guidelines.
Methods:
After a questionnaire-based cross-sectional study performed in 2010, a passive, multimodal intervention, focused on improving adherence to HBPM guidelines, was implemented. A second study was conducted in 2014 to measure its effect.
Results:
In 2010 and 2014, 1010 and 1005 patients, respectively, completed the questionnaire. In 2010 and 2014, 82% and 84% of patients, respectively, self-measured their BP. Reporting of HBPM and adherence to recommended procedures was suboptimal. Only 34.0% of patients in 2010 and 31.7% in 2014 brought > 80% of their measurements to their doctor. Only 49.6% in 2010 and 52.9% in 2014 prepared > 80% of the time for HBPM. Only 48.1% in 2010 and 52.1% in 2014 rested for 5 minutes > 80% of the time before HBPM. Only 15% of patients in 2010 and 18% in 2014 were defined as sufficiently compliant with all HBPM procedures. Paired analysis of a subset of 535 patients who participated in the 2010 and 2014 studies showed no clinically significant differences in reliability between the 2 surveys.
Conclusions:
Adherence to HBPM guidelines was suboptimal in 2010 and still is in 2014 despite a passive, multimodal intervention. Active training in HBPM procedures should be studied. Greater automation could improve HBPM reliability.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: