Related Experiment Video
Updated: Apr 13, 2026

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
International normalized ratio stability in warfarin-experienced patients with nonvalvular atrial fibrillation
Winnie W Nelson1, Sunita Desai, Chandrasekharrao V Damaraju
1Health Economics and Outcomes Research (HECOR), Janssen Scientific Affairs, LLC, 1000 US Highway 202 South, Raritan, NJ, 08869, USA, wnelson@its.jnj.com.
Background:
Maintaining stable levels of anticoagulation using warfarin therapy is challenging. Few studies have examined the stability of the international normalized ratio (INR) in patients with nonvalvular atrial fibrillation (NVAF) who have had ≥6 months' exposure to warfarin anticoagulation for stroke prevention.
Objective:
Our objective was to describe INR control in NVAF patients who had been receiving warfarin for at least 6 months.
Methods:
Using retrospective patient data from the CoagClinic™ database, we analyzed data from NVAF patients treated with warfarin to assess the quality of INR control and possible predictors of poor INR control. Time within, above, and below the recommended INR range (2.0-3.0) was calculated for patients who had received warfarin for ≥6 months and had three or more INR values. The analysis also assessed INR patterns and resource utilization of patients with an INR >4.0. Logistic regression models were used to determine factors associated with poor INR control.
Results:
Patients (n = 9433) had an average of 1.6 measurements per 30 days. Mean follow-up time was 544 days. Approximately 39% of INR values were out of range, with 23% of INR values being <2.0 and 16% being >3.0. Mean percent time with INR in therapeutic range was 67%; INR <2.0 was 19% and INR >3.0 was 14%. Patients with more than one reading of INR >4.0 (~39%) required an average of one more visit and took 3 weeks to return to an in-range INR. Male sex and age >75 years were predictive of better INR control, whereas a history of heart failure or diabetes were predictive of out-of-range INR values. However, patient characteristics did not predict the likelihood of INR >4.0.
Conclusions:
Out-of-range INR values remain frequent in patients with NVAF treated with warfarin. Exposure to high INR values was common, resulting in increased resource utilization.
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Venous Thrombosis III: Interprofessional Care
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Therapeutic Index
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Venous Thrombosis IV: Nursing Management

