Related Experiment Video
Updated: Aug 2, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
The requirement of extracorporeal circulation system for transluminal aortic valve replacement: Do we really need it
Konstantinos Toutouzas1, Andreas Synetos1, George Latsios1
1First Department of Cardiology, Hippokration Hospital, Athens Medical School, Athens, Greece.
Abstract:
Transcatheter aortic valve replacement (TAVR) is the mainstay for treating high-risk patients with aortic stenosis. As the TAVR procedures worldwide keep increasing, it is inevitable that more issues and complications will arise. Such a complication that merits attention is the conversion of TAVR into open-heart surgery and the necessity this complication creates to have an extracorporeal circulation system in the catheterization laboratory. This review contains an analysis of all major randomized trials and registries on the number and cause of TAVR procedures that ended up in open-heart surgery and presents data to challenge the prerequisite of extracorporeal circulation system in the cath laboratory. © 2015 Wiley Periodicals, Inc.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization