Related Experiment Video For Cancer
Updated: Apr 12, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
White-Light or Narrow-Band Imaging Colonoscopy in Surveillance of Ulcerative Colitis: A Prospective Multicenter Study
Ludger Leifeld1, Gerhard Rogler2, Andreas Stallmach3
1Department of Internal Medicine, Evangelisches Krankenhaus Kalk, Cologne, Germany.
Background & Aims:
Early detection of neoplastic lesions is essential in patients with long-standing ulcerative colitis but the best technique of colonoscopy still is controversial.
Methods:
We performed a prospective multicenter study in patients with long-standing ulcerative colitis. Two colonoscopies were performed in each patient within 3 weeks to 3 months. In white-light (WL) colonoscopy, stepwise random biopsy specimens (4 biopsy specimens every 10 cm), segmental random biopsies (2 biopsy specimens in 5 segments), and targeted biopsy specimens were taken. In NBI colonoscopy, segmental and targeted biopsy specimens were taken. The sequence of WL and NBI colonoscopy was randomized.
Results:
In 36 of 159 patients enrolled (22.6%), 54 lesions with intraepithelial neoplasia (IN) were found (51 low-grade, 3 high-grade). In WL colonoscopy we found 11 IN in stepwise biopsy specimens, 4 in segmental biopsy specimens, and 15 in targeted biopsy specimens. In NBI colonoscopy 7 IN were detected in segmental biopsy specimens and 24 IN were detected in targeted biopsy specimens. Almost all IN were found with one technique alone (κ value of WL vs NBI, -0.86; P < .001). Statistically equivalent numbers of IN were found in NBI colonoscopy with targeted and segmental biopsy specimens as in WL colonoscopy with targeted and stepwise biopsy specimens, but with fewer biopsy specimens (11.9 vs 38.6 biopsy specimens, respectively; P < .001), and less withdrawal time was necessary (23 vs 13 min, respectively; P < .001).
Conclusions:
Stepwise biopsy specimens are indispensable in WL colonoscopy. The combination of targeted and segmental biopsy specimens in the NBI technique is as sensitive as targeted together with stepwise biopsy specimens in WL colonoscopy, but requires fewer biopsy specimens and less time. The highest sensitivity should be reached by combining the WL and NBI techniques by switching between the modes.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
10:35Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures III: Video Capsule Endoscopy
Drugs for Treatment of Ulcerative Colitis in IBD