Estimation of respiratory rate from photoplethysmographic imaging videos compared to pulse oximetry
Abstract:
We present a study evaluating two respiratory rate estimation algorithms using videos obtained from placing a finger on the camera lens of a mobile phone. The two algorithms, based on Smart Fusion and empirical mode decomposition (EMD), consist of previously developed signal processing methods to detect features and extract respiratory induced variations in photoplethysmographic signals to estimate respiratory rate. With custom-built software on an Android phone, photoplethysmographic imaging videos were recorded from 19 healthy adults while breathing spontaneously at respiratory rates between 6 to 32 breaths/min. Signals from two pulse oximeters were simultaneously recorded to compare the algorithms' performance using mobile phone data and clinical data. Capnometry was recorded to obtain reference respiratory rates. Two hundred seventy-two recordings were analyzed. The Smart Fusion algorithm reported 39 recordings with insufficient respiratory information from the photoplethysmographic imaging data. Of the 232 remaining recordings, a root mean square error (RMSE) of 6 breaths/min was obtained. The RMSE for the pulse oximeter data was lower at 2.3 breaths/min. RMSE for the EMD method was higher throughout all data sources as, unlike the Smart Fusion, the EMD method did not screen for inconsistent results. The study showed that it is feasible to estimate respiratory rates by placing a finger on a mobile phone camera, but that it becomes increasingly challenging at respiratory rates greater than 20 breaths/min, independent of data source or algorithm tested.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Volumes and Capacities I