Related Experiment Video
Updated: Apr 12, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Metaphyseal tibial level (MTL) screws: a modified percutaneous technique for lateral plateau depression fractures
Frédéric Vauclair1, Mahmoud Almasri, Nicolas Gallusser
1Département de l'appareil locomoteur, Service d'orthopédie et traumatologie, Centre Hospitalier Universitaire Vaudois, Rue du Bugnon 46, BH 10-238, 1011, Lausanne, Switzerland, frederic.vauclair@chuv.ch.
Introduction:
Lateral tibial plateau fractures are more frequent than medial fractures, and those with articular depression are particularly challenging because of high displacement risk. To prevent secondary subsidence, the gold standard is raft screws with a periarticular or anti-glide plate. Graft is used to fill the metaphyseal defect created by reduction in the depressed fragment. We present a case of Schatzker II fracture managed in a complete percutaneous fashion, with a new combined technique of raft screws and interference screw used as a support.
Case Report:
A 51-year-old female sustained a Schatzker II tibial plateau fracture. Based on pre-operative CT, direction of reduction force to apply was drawn on coronal and sagittal cuts.
Operative Technique:
Under fluoroscopic control, the split component of the fracture was reduced. The cortical window was then drilled in the lateral cortex, and a K wire advanced under the depressed fragment under fluoroscopic guidance. After fragment reduction with a bone impacter, internal fixation was completed by percutaneous introduction of two subchondral cortical screws. A bioabsorbable interference screw was then introduced in the impacter tunnel to support impacted bone under the reduced articular surface. Finally, a cortical screw was introduced, from anterior to posterior to prevent screw cut-out.
Conclusion:
The combination of subchondral screws in a jail technique with a bioabsorbable interference screw that we named metaphyseal tibia level (MTL) screw technique is, to our knowledge, not described. The MTL screw promises to be a true percutaneous reduction and fixation technique for Schatzker II and III fractures in patients with reasonable bone quality.
More Related Videos
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...