Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Endoscopic Procedures III: Video Capsule Endoscopy01:28

Endoscopic Procedures III: Video Capsule Endoscopy

1.3K
Capsule endoscopy, or wireless or video capsule endoscopy, is a diagnostic procedure for examining the entire gastrointestinal tract. Patients swallow a capsule about the size of a vitamin tablet. The capsule is equipped with a transmitter, a battery, an LED light source, and a color video camera to capture images throughout the gastrointestinal tract. This procedure is particularly useful for diagnosing conditions such as Crohn's disease, ulcerative colitis, tumors, polyps, ulcers,...
1.3K
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy01:26

Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy

1.1K
Sigmoidoscopy and laparoscopy are distinct medical procedures that enable physicians to internally inspect different parts of the GI tract. Although they serve different purposes, each is essential for diagnosing and, in some cases, treating various medical conditions.
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical performance of the urine-based TERT promoter AbsoluteQ Digital PCR for non-invasive detection of bladder cancer.

Molecular oncology·2026
Same author

Fabrication of Electrospun PCL/PEO Microfibers with Fe<sub>3</sub>O<sub>4</sub> Nanoparticles for Magnetic Hyperthermia: Immunocompatibility Assessment Using CD14+ Monocytes, CD4+ and CD8+ T Cells, and CD56+ NK Cells <i>In Vitro</i>.

ACS biomaterials science & engineering·2026
Same author

HSP90 inhibition potentiates oxidant-based antimelanoma action of novel thioquercetin derivatives by compromising AhR/CYP1A1 pathway.

Apoptosis : an international journal on programmed cell death·2026
Same author

Structures, characteristics, and anticancer mechanisms of taxanes, beta-glucans, and isothiocyanates.

Molecular biology reports·2026
Same author

A new biocompatible amino-Gd-metallofullerenol (Amino-Gd-FulOH) nanoplatform as a potential MRI contrast agent and its effect on macrophages.

Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie·2025
Same author

Evaluating the relationship between microplastics and nanoplastics contamination and diverse cancer types development.

Environmental pollution (Barking, Essex : 1987)·2025

Related Experiment Video

Updated: Apr 12, 2026

Author Spotlight: Advancing Hepatobiliary and Pancreatic Tumor Treatment with Minimally Invasive Surgical Techniques
03:33

Author Spotlight: Advancing Hepatobiliary and Pancreatic Tumor Treatment with Minimally Invasive Surgical Techniques

Published on: September 27, 2024

1.6K

Video display during laparoscopy - where should it be placed?

Dominik A Walczak1, Dariusz Pawełczak2, Piotr Piotrowski3

  • 1Department of General Surgery, John Paul II Memorial Hospital, Belchatow, Poland ; Department of Experimental Surgery, Medical University of Lodz, Lodz, Poland.

Wideochirurgia I Inne Techniki Maloinwazyjne = Videosurgery and Other Miniinvasive Techniques
|May 12, 2015
PubMed
Summary
This summary is machine-generated.

Lowering the laparoscopic monitor improves surgical performance and hand-eye coordination. This ergonomic adjustment benefits surgeons, especially those with prior laparoscopy experience, by optimizing the surgical view.

Keywords:
ergonomicslaparoscopymonitorsurgical trainingvideo display

More Related Videos

Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery
04:03

Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery

Published on: March 28, 2025

661
Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
06:39

Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor

Published on: May 23, 2025

566

Related Experiment Videos

Last Updated: Apr 12, 2026

Author Spotlight: Advancing Hepatobiliary and Pancreatic Tumor Treatment with Minimally Invasive Surgical Techniques
03:33

Author Spotlight: Advancing Hepatobiliary and Pancreatic Tumor Treatment with Minimally Invasive Surgical Techniques

Published on: September 27, 2024

1.6K
Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery
04:03

Application of Laparoscopic Ultrasonography in Primary Choledochal Suture during Combined Two-lens Surgery

Published on: March 28, 2025

661
Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor
06:39

Three-dimensional Location Approach with Silk Thread Guided Laparoscopic Segmentectomy for Liver Tumor

Published on: May 23, 2025

566

Area of Science:

  • Minimally Invasive Surgery
  • Surgical Ergonomics
  • Medical Simulation

Background:

  • Standard laparoscopic monitor placement at eye level compromises surgeon ergonomics and hand-eye coordination.
  • The endoscope's viewing axis and instrument handle mechanics create a visual-motor mismatch during laparoscopy.
  • Optimal head flexion for surgical tasks is between 15-45 degrees.

Purpose of the Study:

  • To investigate the impact of laparoscopic monitor placement on surgical task performance.
  • To assess if monitor height influences hand-eye coordination in a simulated laparoscopic environment.

Main Methods:

  • Fifty-two medical students performed a simulated suturing task using a laparoscopic simulator.
  • Performance was measured across two monitor positions: standard eye-level and a lower position on the simulator.
  • Monitor placement order was randomized to control for learning effects.

Main Results:

  • Tasks were completed significantly faster with the monitor placed lower on the simulator, forcing a downward gaze.
  • A lower monitor position demonstrated a greater performance benefit for participants with prior laparoscopy experience.

Conclusions:

  • Adjusting monitor placement to a lower, more ergonomic position enhances laparoscopic performance.
  • Future surgical technologies should prioritize patient-integrated displays to improve surgeon ergonomics.