Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
The five-minute prebreathe in evaluating carbon dioxide absorption in a closed-circuit rebreather: a randomized
Carolyn Deng1, Neal W Pollock2, Nicholas Gant3
1Department of Anaesthesiology, University of Auckland.
Introduction:
Closed-circuit underwater rebreather apparatus (CCR) recycles expired gas through a carbon dioxide (CO₂) 'scrubber'. Prior to diving, users perform a five-minute 'prebreathe' during which they self-check for symptoms of hypercapnia that might indicate a failure in the scrubber. There is doubt that this strategy is valid.
Methods:
Thirty divers were block-randomized to breathe for five minutes on a circuit in two of the following three conditions: normal scrubber, partly-failed scrubber, and absent scrubber. Subjects were blind to trial allocation and instructed to terminate the prebreathe on suspicion of hypercapnia.
Results:
Early termination was seen in 0/20, 2/20, and 15/20 of the normal, partly-failed, and absent absorber conditions, respectively. Subjects in the absent group experienced a steady, uncontrolled rise in inspired (PICO₂) and end-tidal CO₂ (PETCO₂). Seven subjects exhibited little or no increase in minute volume yet reported dyspnoea at termination, suggesting a biochemically-mediated stimulus to terminate. This was consistent with results in the partly-failed condition (which resulted in a plateaued mean PICO₂ near 20 mmHg), where a small increase in ventilation typically compensated for the inspired CO₂ increase. Consequently, mean PETCO₂ did not change and in the absence of a hypercapnic biochemical stimulus, subjects were very insensitive to this condition.
Conclusions:
While prebreathes are useful to evaluate other primary functions, the five-minute prebreathe is insensitive for CO₂ scrubber faults in a rebreather. Partly-failed conditions are dangerous because most will not be detected at the surface, even though they may become very important at depth.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Acute Respiratory Failure-III
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...