Multi-line transmission combined with minimum variance beamforming in medical ultrasound imaging
Abstract:
Increasing medical ultrasound imaging frame rate is important in several applications such as cardiac diagnostic imaging, where it is desirable to be able to examine the temporal behavior of fast phases in the cardiac cycle. This is particularly true in 3-D imaging, where current frame rate is still much slower than standard 2-D, B-mode imaging. Recently, a method that increases frame rate, labeled multi-line transmission (MLT), was reintroduced and analyzed. In MLT scanning, the transmission is simultaneously focused at several directions. This scan mode introduces artifacts that stem from the overlaps of the receive main lobe with the transmit side lobes of additional transmit directions besides the one of interest. Similar overlaps occur between the transmit main lobe with receive side lobes. These artifacts are known in the signal processing community as cross-talk. Previous studies have concentrated on proper transmit and receive apodization, as well as transmit directions arrangement in the transmit event, to reduce the cross-talk artifacts. This study examines the possibility of using adaptive beamforming, specifically, minimum variance (MV) and linearly constrained minimum variance (LCMV) beamforming, to reduce the cross-talk artifacts, and maintain or even improve image quality characteristics. Simulation results, as well as experimental phantom and in vivo cardiac data, demonstrate the feasibility of reducing cross-talk artifacts with MV beamforming. The MV and LCMV results achieve superior spatial resolution, not only over other MLT methods with data-independent apodization, but even over that of single-line transmission (SLT) without receive apodization. The MV beamformer is shown to be less sensitive to wider transmit profiles required to reduce the transmit crosstalk artifacts. MV beamforming, combined with the wider transmit profiles, can provide a good approach for MLT scanning with reduced cross-talk artifacts, without compromising spatial resolution, and even improving it. We also demonstrate that the MV and LCMV beamformers lead to almost identical results. This is because of their very similar beampatterns, except for the sharp nullifying properties that the LCMV beamformer has around interfering beams.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography