Related Experiment Video
Updated: Apr 12, 2026

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Technical note: unsafe rectal temperature measurements due to delayed warming of the thermocouple by using a condom.
Tristan Krap1,2,3, Joris Meurs4, Janine Boertjes5
1Ars Cogniscendi Centre for Legal and Forensic Medicine, Wezep, Netherlands. t.krap@amc.nl.
Abstract:
In some cases, in the Netherlands, an additional layer is being added to the thermocouple, used to measure the rectal temperature in medicolegal death investigations. Because of this deviation from the standard method, questions arose regarding the accuracy and precision of the measured temperature. Therefore, a cooling experiment was carried out on a round body made of agar with an average thermal conductivity of 0.454 W/(m °C) while measuring the temperature with and without an additional layer around the thermocouple for three different starting temperatures: 36, 30, and 27 °C. The results show a significant difference between the measured values for the first 5 min when comparing with and without the additional layer. Further, a decrease in precision is present within the first minutes when using an additional layer. Therefore, it is concluded that it is best to measure the rectal temperature without an additional layer around the thermocouple and caution should be taken when measuring with an additional layer.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...