Related Experiment Video
Updated: Apr 12, 2026

Translational Rabbit Model of Chronic Cardiac Pacing
Published on: January 6, 2023
Clinical Predictors of Pacemaker Implantation in Patients with Syncope Receiving Implantable Loop Recorder with or
Nauman Ahmed1, Antonio Frontera1, Alexander Carpenter1
1Bristol Heart Institute, University Bristol Hospitals NHS Foundation Trust, Bristol Royal Infirmary, Bristol, United Kingdom.
Background:
Implantable loop recorders (ILR) allow prolonged cardiac rhythm monitoring and improved diagnostic yield in syncope patients. Predictive factors for pacemaker (PM) implantation in the ILR population with unexplained syncope have not been adequately investigated. In this single center, retrospective, observational study we investigated factors that predict PM implantation in this population.
Methods:
We retrospectively analyzed our ILR database of patients aged over 18 years who underwent ILR implantation for unexplained syncope between January 2009 and June 2013. Patient case notes were examined for demographics, history, electrocardiogram (ECG) abnormalities, investigations, and events during follow-up. The primary end-point was the detection of a symptomatic or asymptomatic bradycardia requiring PM implantation.
Results:
During a period of 4.5 years, 200 patients were implanted with ILR for unexplained syncope, of who n = 33 (16.5%) had clinically significant bradycardia requiring PM implantation. After multivariable analysis, history of injury secondary to syncope was found to be the strongest independent predictor for PM implantation (odds ratio [OR]:9.1; P < 0.001; 95% confidence interval [CI]: (3.26-26.81). Other significant predictors included female sex, PR interval > 200msec, and age >75 years. In patients without conduction abnormalities on the ECG, history of injury secondary to syncope was found to be the strongest independent predictor for PM implantation (OR: 8.16; P = 0.00027; 95% [CI]: (2.67-26.27).
Conclusions:
A history of injury secondary to syncope and female sex were independent predictive factors for bradycardia necessitating PM implantation in patients receiving an ILR for syncope with or without ECG conduction abnormalities.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias I: Introduction
Holter Monitor: 24-Hour Monitoring