Accuracy verification of surface energy components measured by inverse gas chromatography
1Department of Pharmacy and Pharmacology, University of Bath, Bath BA2 7AY, UK; Faculty of Pharmacy, University of Damascus, Damascus, Syria.
Abstract:
Inverse gas chromatography (IGC) measures the retention times of probes which are then used to calculate the surface properties of solids. No method is available to verify how much the measured values are close to their accurate values. According to the chromatographic adhesion law, the accurate determination of the dispersive retention factor (K(a)(CH2)) is a necessary prerequisite to obtain accurate surface components. Employing two equations in this paper, %ΔγS(d), which is the percentage deviation of dispersive component (γS(d)) from its accurate value (γS0(d)), was correlated firstly to %CV(ln K(a)(CH2)), the percentage coefficient of variation of ln K(a)(CH2), and secondly to FEK(a)(CH2), the factor error of K(a)(CH2), via two linear equations. The first equation is to outline the upper and lower limits of the uncertainty range of γS0(d), and the second equation is to estimate γS0(d). To minimize the uncertainty range of γS0(d) to less than ±5%, %CV(ln K(a)(CH2)) should be less than 0.7%. Then considering the sign of FEK(a)(CH2) narrows the uncertainty range to either its upper or lower half.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Volatilization
Surface Tension and Surface Energy
Consider a beaker filled with liquid. The bulk molecules in the liquid experience equal attractive forces on all sides with the surrounding molecules. However, the surface molecules experience a net attractive force downward due to the bulk molecules. The surface of the liquid behaves like a stretched membrane,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...