Spectrometer calibration protocol for Raman spectra recorded with different excitation wavelengths
T W Bocklitz1, T Dörfer1, R Heinke1
1Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich-Schiller-University, Helmholtzweg 4, 07743 Jena, Germany; Leibniz Institute of Photonic Technology, Albert Einstein Straße 7, 07745 Jena, Germany.
Abstract:
The combination of Raman spectroscopy with chemometrics has gained significant importance within the last years to address a broad variety of biomedical and life science questions. However, the routine application of chemometric models to analyze Raman spectra recorded with Raman devices different from the device used to establish the model is extremely challenging due to Raman device specific influences on the recorded Raman spectra. Here we report on the influence of different non-resonant excitation wavelengths on Raman spectra and propose a calibration routine, which corrects for the main part of the spectral differences between Raman spectra recorded with different (non-resonant) excitation wavelengths. The calibration routine introduced within this contribution is an improvement to the known 'standard' calibration routines and is a starting point for the development of a calibration protocol to generate spectrometer independent Raman spectra. The presented routine ensures that a chemometric model utilizes only Raman information of the sample and not artifacts from small shifts in the excitation wavelength. This is crucial for the application of Raman-spectroscopy in real-world-settings, such as diagnostics of diseases or identification of bacteria.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...