In Vitro Comparative Assessment of Mechanical Blood Damage Induced by Different Hemodialysis Treatments

Ranko Sakota1, Carlo Alberto Lodi1, Sara Antonia Sconziano1

  • 1Research & Development, Gambro Dasco SpA, Medolla (MO), Italy.

Artificial Organs
|May 19, 2015
PubMed

Gradual deterioration of red blood cells (RBCs) due to mechanical stress (chronic hemolysis) is unavoidable during treatments that involve extracorporeal blood circulation, such as hemodialysis (HD). This effect is generally undetectable and does not generate any acute symptoms, but it leads to an increase in plasma free hemoglobin (fHb). There are no absolute safety levels for fHb increase, indicating the need for an empirical evaluation using comparative testing. The increase in fHb levels was investigated in vitro by applying double-needle double-pump HD (HD-DNDP), a new modality in which arterial and venous pumps both run continuously. fHb was measured during typical and worst-case simulated dialysis treatments (double-needle single-pump HD [HD-DNSP], hemodiafiltration [HDF-DN], single-needle double-pump HD [HD-SNDP], and HD-DNDP) performed in vitro using bovine blood for 4 h. Hemolysis-related indices (fHb%; index of hemolysis, IH; and normalized IH) were calculated and used for comparison. The increase in fHb during either HDF-DN or HD-SNDP with Artis and AK200 dialysis machines was similar, while the fHb at the maximum real blood flow rate (Qbreal ) at the completion of the HD-DNDP treatment on Artis was higher than that for HD-DNSP using a Phoenix dialysis machine (fHb% = 1.24 ± 0.13 and 0.92 ± 0.12 for the Artis machine with HD-DNDP at Qbreal  = 450 mL/min and Phoenix with HD-DNSP at Qbreal  = 500 mL/min, respectively). However, the fHb levels increased linearly, and no steep changes were observed. The increases observed during HD-DNDP were the same order of magnitude as those for widely used bloodlines and treatment modes for delivering dialysis treatments. The observed results matched literature findings, and thus the measured fHb trends are not predicted to have clinical side effects. HD-DNDP treatment with Artis does not merit any additional concern regarding mechanical stress to RBCs compared with that observed for routinely used dialysis treatments, bloodlines and machines. Although the in vitro measurement of the fHb increase in bovine blood does not allow a prediction of the absolute level of blood mechanical damage or the possible effects in humans, such measurements are valuable for assessing hemolytic harm by performing tests comparing the proposed treatment with existing devices.

Related Concept Videos

Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
3.5K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.9K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.6K
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...