Related Experiment Video
Updated: Apr 12, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Tracheal intubation in patients with anticipated difficult airway using Boedeker intubation forceps and McGrath
C Strøm1, S Barnung1, M S Kristensen1
1Department of Anaesthesia, Centre of Head and Orthopaedics, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark.
Background:
Videolaryngoscopes with sharp angulated blades improve the view of the vocal cords but this does not necessarily result in higher success rates of intubation The aim of this study was to evaluate the efficacy of using Boedeker intubation forceps in conjunction with McGrath Series 5 Videolaryngoscope (MVL) in patients with predictors for difficult intubation.
Methods:
The study was conducted at the Department of Anaesthesia, Copenhagen University Hospital from September to December 2013. Patients with one or more predictors of difficult intubation scheduled for general anaesthesia were assessed for eligibility. Patients were intubated using Boedeker intubation forceps and MVL. The primary endpoint was time to intubation. The secondary endpoints were intubation success rate, number of intubation attempts, intubation conditions and post-operative hoarseness.
Results:
Thirty-three patients were assessed for eligibility, and 25 patients were included in the study with a median SARI score of 3 (IQR 3-4). Twenty-two (88%, 95% confidence interval [74-100%]) of the patients were successfully intubated by the method with a median time to intubation of 115 s (IQR 78-247). Steering and advancement of the tube were reported as acceptable in 21 (84%) and 22 cases (88%), respectively, and excellent in 10 cases (45%) for both measures. Ten cases (40%) were intubated on the first attempt. There were three cases (12%) of failed intubation; in these cases, successful intubation was obtained by using a styletted tube.
Conclusion(S):
Most patients with anticipated difficult intubation can be successfully intubated with Boedeker intubation forceps and MVL. However, endotracheal tube placement failed in 3/25 patients despite a good laryngeal view.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning II: Procedure
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...