Radioprotective lightweight caps in the interventional cardiology setting: a randomised controlled trial (PROTECT)
Heiko Uthoff1, Ramon Quesada, Jonathan S Roberts
1Department of Interventional Cardiology, Baptist Cardiac and Vascular Institute, Miami, FL, USA.
Aims:
The aim of this study was to test the radioprotection efficacy and comfort of newer bilayer barium sulphate-bismuth oxide composite (XPF) caps in an interventional cardiology setting.
Methods And Results:
Operators were randomly assigned to wear standard fabric (n=59), 0.3 mm (n=74), or 0.5 mm (n=64) lead-equivalent XPF caps. Radiation doses were measured by using dosimeters placed outside and underneath the caps. Wearing comfort was assessed at the end of each measurement on a visual analogue scale (VAS) (0-100, with 100 indicating optimal comfort). Procedural data did not differ between the XPF and standard groups. Mean standard, XPF 0.3 mm, and XPF 0.5 mm cap weights were 12.5 g, 118.4 g, and 123.7 g, respectively. VAS comfort ratings of the standard and XPF caps did not differ significantly (p=0.272). The mean radiation protection was 12.0%, 95% CI: 4.9-19.1% (standard caps, n=35), 91.5%, 95% CI: 87.4-95.6% (XPF 0.3 mm caps, n=45) and 97.1%, 95% CI: 92.5-100% (XPF 0.5 mm caps, n=44) (p≤0.001 for all group comparisons). Using the XPF caps, a cumulative total radiation dose reduction by almost factor 10 was evident (272 procedures, 22,310 μSv outside the XPF caps, 2,770 μSv inside the caps).
Conclusions:
Lightweight XPF caps show comparable comfort to standard fabric caps, but provide substantial radiation protection during fluoroscopy-guided cardiac interventions.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
PPE Use in Healthcare Settings I: Donning
Cardiopulmonary Resuscitation III: AED Use