Related Experiment Video
Updated: Apr 12, 2026

Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
Comparison of Clinical Features in Highly Myopic Eyes with and without a Dome-Shaped Macula
I-Chia Liang1, Noriaki Shimada2, Yuichiro Tanaka2
1Department of Ophthalmology and Visual Science, Tokyo Medical and Dental University, Tokyo, Japan; Department of Ophthalmology, Cathay General Hospital, Taipei, Taiwan.
Purpose:
To compare the clinical features of highly myopic eyes with a dome-shaped macula (DSM) with those without a DSM and to identify the funduscopic clues to suspect the presence of DSM.
Design:
Retrospective case series.
Patients:
A total of 586 patients (1118 eyes) with high myopia (refractive error <-8 diopters [D] or axial length ≥26.5 mm) who had optical coherence tomography (OCT) examinations through the central fovea at our High Myopia Clinic between February 2012 and November 2013.
Methods:
Vertical and horizontal OCT scans across the central fovea were retrospectively analyzed. A DSM was defined by the presence of an inward bulge of >50 μm in the vertical OCT image. Fundus photographs also were analyzed to identify the funduscopic clues to suspect the presence of DSM.
Main Outcome Measures:
The rate of DSM in 1118 highly myopic eyes. The rate of DSM in highly myopic eyes with macular complications. Funduscopic features to suggest the presence of DSM.
Results:
Among the 1118 eyes, 225 (20.1%) had a DSM. A DSM was present in both vertical and horizontal OCT sections in 20% of eyes, along only the vertical section in 77% of eyes, and in only the horizontal section in 2% of eyes. The results of multiple regression analyses showed that serous retinal detachment and foveal and extrafoveal retinoschisis were significantly associated with the presence of DSM and that choroidal neovascularization was not. Ophthalmoscopically, 91.4% of the eyes with the appearance of a horizontal ridge connecting the optic disc and the fovea had a DSM.
Conclusions:
A DSM is found in as many as 20% of highly myopic individuals. Horizontal ridges connecting the optic disc and the fovea might be an important clue to suspect the presence of a DSM on the basis of fundus photographs.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
Related Concept Videos
Glaucoma: Overview
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment