Related Experiment Video
Updated: Apr 12, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Cardiac memory in cardiac resynchronization therapy: A vectorcardiographic comparison of biventricular and left
Laura Perrotta1, Giuseppe Ricciardi1, Paolo Pieragnoli1
1University of Florence, Italy.
Introduction:
"Cardiac memory" (CM) refers to a change in repolarization induced by an altered pathway of activation, manifested after resumption of spontaneous ventricular activation (SVA).
Aims:
To investigate for the first time in humans the effects of left ventricular (LV) pacing on CM development through vectorcardiography (VCG).
Methods:
We studied 28 patients with heart failure (HF) and left bundle branch block (LBBB) treated with cardiac resynchronization therapy (CRT). Fourteen patients underwent biventricular (BIV) stimulation; the other 14 underwent LV stimulation only. VCG was acquired during SVA at baseline and during AAI and DDD pacing immediately after and 7 and 90 days after the implant.
Results:
At baseline, in both groups, the QRS and T vectors angles were those specific of LBBB pattern. During DDD pacing, QRS vector angle changed to the right and upward in BIV patients while no significant differences were observed in LV patients. During AAI pacing, T vector angle changed significantly in BIV patients, following the direction of the paced QRS and amplitude significantly increased. In LV patients no significant differences in T vector angles were observed. Only T vector amplitude significantly increased at 7 days (p=0.03) and at 90 days (p=0.008 vs baseline).
Conclusion:
In patients with LBBB, BIV pacing induces cardiac memory development as a significant change in T vector magnitude and angle, while LV pacing doesn't induce significant modifications in QRS and T vector angles and CM is manifested only as a significant T vector amplitude change.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Cardiomyopathy II: Dilated Cardiomyopathy
Electrophysiology of Normal Cardiac Rhythm
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...