Related Experiment Video
Updated: Apr 12, 2026

Endoscopic Septoplasty with Limited Two-line Resection: Minimally Invasive Surgery for Septal Deviation
Published on: June 20, 2018
Assessment of nasal patency after rhinoplasty through the Glatzel mirror
Victor Diniz de Pochat1, Nivaldo Alonso2, Rogério Rafael da Silva Mendes3
1MD, PhD. Substitute Associate Professor of Plastic Surgery in the Federal University of Bahia - Medical School.
Introduction:
OBJECTIVE evaluation of nasal function is a constant challenge for plastic surgeons, otolaryngologists, and allergists. The modified Glatzel mirror can evaluate nasal expiratory flow; however, there is little information on this method and its use in the measurement of nasal patency after surgical procedures.
Objective:
To compare, in a prospective study, the functional results before and after cosmetic rhinoplasty and evaluate the use of the Glatzel mirror as an objective method to assess nasal patency.
Methods:
To achieve this objective, we analyzed the functional results of surgery through a subjective questionnaire and objective evaluation through a modified Glatzel mirror, and evaluated the correlation between the 2 methods. Twenty patients (14 women and 6 men) underwent aesthetic rhinoplasty using spreader grafts. Pre- and postoperative evaluation (90-120 days) included a respiratory quality score (subjective) and modified Glatzel mirror test (objective). Subsequently, the Spearman test was used to compare the pre- and postoperative subjective and objective data.
Results:
The subjective evaluation demonstrated a statistical difference between pre- and postoperative scores (8 ± 2 and 9.4 ± 0.7, P ≤ 0.001). There was no statistical difference in mean nasal patency by modified Glatzel mirror. No statistically significant correlation was observed when comparing the modified Glatzel mirror values with the subjective scores reported by patients pre- or postoperatively.
Conclusion:
The Glatzel method lacks sensitivity in detecting patient-reported improvements in breathing following rhinoplasty. This suggests that the method is a poor assessment tool to detect small, post-surgical changes in the nasal airways.
More Related Videos
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Epistaxis
Etiology
Possible causes of this condition include high blood pressure, trauma, low humidity, upper respiratory tract infections, allergies, foreign bodies, nasal inhalation of corticosteroids or illicit drugs, excessive use of decongestant nasal sprays, facial or nasal surgery, anatomic malformation, tumors, or systemic...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...