Objective:
To establish standardized methods and parameters of the isolated heart coronary angiography through the experiment of in vitro porcine heart by MSCT.
Methods:
Based on different perfusion volume (50, 60 and 70 mL) and different perfusion-imaging time (5, 10 and 20 min), the in vitro porcine coronary artery was injected liposoluble and water-soluble contrast agents using remodel angiography equipment and scanned by MSCT. And the 3D image results were compared. The images were recorded and evaluated by 2 radiologists and analyzed by statistical software.
Results:
Liposoluble contrast agent affected the images by damaging and infiltrating the fats around the coronary artery, while the water-soluble contrast agent didn't affect the images. The groups with 60 mL or 70 mL perfusion and 5 min perfusion-imaging time had the best images.
Conclusion:
The suitable parameters of the angiography lay the foundation of postmortem coronary angiography.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...