Ground cross-modal impedance as a tool for analyzing ground/plate interaction and ground wave propagation

L Grau1, B Laulagnet1

  • 1INSA Lyon, Departement Genie Mecanique et Conception, Laboratoire Vibrations et Acoustique, 25 bis av. Jean Capelle, 69100 Villeurbanne, France.

Related Concept Videos

Mesh Analysis for AC Circuits01:12

Mesh Analysis for AC Circuits

In the domain of radio communication, the significance of impedance matching must be considered. It is crucial to ensure the efficient transmission of signals between radio transmitters and receivers. Achieving this balance involves using impedance-matching circuits, with one fundamental configuration comprising a resistor, capacitor, and inductor.
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
792
Taping Over Different Ground Profiles01:12

Taping Over Different Ground Profiles

Taping over varying ground profiles requires careful adaptation to achieve accurate measurements. On smooth, level ground with minimal vegetation, the tape can rest directly on the ground. Here, the taping team, typically consisting of a head and a rear tapeman, coordinates their positions with clear communication. The rear tapeman holds the tape at the starting point and guides the head tapeman toward a range pole placed beyond the endpoint, using hand or voice signals to ensure alignment.On...
463
Series Impedances: Three-Phase Line01:27

Series Impedances: Three-Phase Line

Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
530
Bode Plots Construction01:24

Bode Plots Construction

The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
1.3K
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
503
Shunt Admittances01:26

Shunt Admittances

Shunt admittances play a crucial role in the analysis of transmission lines, particularly for three-phase systems with neutral conductors. When a uniformly charged conductor is positioned above the Earth, it induces an equal but opposite charge on its surface. This interaction creates electric field lines between the conductor and the Earth.
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
636