Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The impact of pain in children and adolescents with cerebral palsy: A daily diary study.

Acta psychologica·2026
Same author

Reasoning in machine vision by learning fast and slow thinking.

Nature communications·2026
Same author

Microbiome-behavior coupling shapes infant adaptation to early maternal unpredictability.

Frontiers in microbiology·2026
Same author

InnerEye-HS: a disease-agnostic clinical tool for hippocampal segmentation.

Brain communications·2026
Same author

Towards generalisable foundation models for brain MRI.

Npj imaging·2026
Same author

Caregiver-reported sleep problems and suicidality in autistic youth: findings from a sleep diary study.

Frontiers in psychiatry·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
Same journal

Evaluation of Phantom Doping Materials in Quantitative Susceptibility Mapping.

Magnetic resonance in medicine·2026
Same journal

Design of an 8-Channel Transmit 32-Channel Receive 11.7T Head Coil and Evaluation of SNR Gains.

Magnetic resonance in medicine·2026
Same journal

The Potential for Absolute Temperature Imaging Based on Brain Metabolites Using an FID-Shifting Approach in Gradient Echo Planar Spectroscopic Imaging (GREPSI).

Magnetic resonance in medicine·2026
Same journal

Prospective Head Motion Correction in T1- and T2-Weighted Long Echo Train Sequences Using Servo Navigation.

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: Apr 12, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

27.2K

Microstructural parameter estimation in vivo using diffusion MRI and structured prior information.

Jonathan D Clayden1, Zoltan Nagy2,3, Nikolaus Weiskopf2

  • 1UCL Institute of Child Health, University College London, London, UK.

Magnetic Resonance in Medicine
|May 22, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a new method to estimate the size of nerve fibers in the human brain using standard hospital scanners. By combining a specific scanning technique with mathematical models that incorporate prior knowledge, researchers successfully mapped these microscopic structures in healthy volunteers. This approach improves the accuracy of brain imaging without requiring specialized, high-power equipment.

Keywords:
BayesianMCMCdual spin-echomicrostructurepriortwice-refocused spin-echowhite matter imagingBayesian modelingneuroimaging physicsclinical scanners

Frequently Asked Questions

More Related Videos

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

11.0K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.3K

Related Experiment Videos

Last Updated: Apr 12, 2026

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging
17:06

Co-analysis of Brain Structure and Function using fMRI and Diffusion-weighted Imaging

Published on: November 8, 2012

27.2K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

11.0K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.3K

Area of Science:

  • Neuroimaging research within diffusion MRI physics
  • Biomedical engineering for clinical diagnostics

Background:

No prior work had resolved how to reliably map nerve fiber dimensions using standard clinical hardware. Researchers often rely on high-power laboratory scanners to detect these minute structural variations. That uncertainty drove the need for more accessible diagnostic tools. Prior research has shown that detailed mathematical modeling can infer tissue properties from magnetic resonance signals. However, these models frequently require extreme gradient strengths unavailable in typical hospital settings. This gap motivated the development of techniques that function under modest hardware constraints. Previous studies primarily focused on post-mortem samples to validate these complex imaging frameworks. The current investigation addresses the limitations of applying such sophisticated models to living human subjects.

Purpose Of The Study:

The researchers aimed to estimate microstructural parameters in living human brains using standard clinical imaging hardware. This study addresses the difficulty of performing high-resolution tissue imaging outside of specialized laboratory environments. The authors sought to overcome the hardware limitations that typically hinder the measurement of nerve fiber dimensions. They investigated whether a Bayesian fitting approach could enhance the reliability of these estimates. The team intended to demonstrate that structured prior information can improve precision without introducing bias. This work addresses the need for accessible methods to probe brain tissue architecture in clinical settings. The researchers aimed to validate their protocol by achieving reproducible contrast in healthy adult volunteers. They motivated this study by highlighting the gap between powerful ex vivo scanners and the modest capabilities of hospital-based systems.

Main Methods:

The team implemented an optimized dual spin-echo diffusion sequence to acquire data from healthy adult volunteers. They applied a Bayesian fitting approach to process the resulting signals. This strategy incorporates structured prior information to constrain the mathematical model. The researchers utilized clinical scanners operating at a gradient strength of 35 mT m(-1). They evaluated the reproducibility of the generated maps by calculating histogram overlap percentages. The analysis focused on estimating the axon radius index across various white matter regions. This design avoids the need for specialized high-power laboratory hardware. The approach systematically compares the precision of estimates with and without the application of influential priors.

Main Results:

The researchers achieved a 7-fold reduction in voxelwise coefficient of variation for axon radius estimates in vivo. They reported a histogram overlap of up to 92% in healthy adult subjects. The study identified sensitivity to larger nerve fibers between 3 and 15 micrometers at clinical field strengths. These results demonstrate that reproducible contrast is obtainable using a gradient strength of 35 mT m(-1). The authors observed no significant bias when applying their structured prior information. Their findings indicate that the model performs effectively despite the constraints of standard hospital equipment. The data suggest that the dual spin-echo sequence maintains stability during the imaging process. The results confirm that precision improvements are attainable through the integration of informative constraints.

Conclusions:

The authors suggest that their Bayesian framework enhances the reliability of nerve fiber measurements in living subjects. This synthesis implies that incorporating structured information helps overcome hardware limitations during standard clinical examinations. The researchers propose that their specific sequence design offers favorable properties for future high-gradient applications. They caution that interpreting these maps requires awareness of model simplifications regarding complex brain tissue architecture. The study indicates that sensitivity to larger nerve fibers remains achievable at standard field strengths. This work demonstrates that precision gains are possible without introducing significant systematic errors. The findings highlight the potential for broader clinical adoption of microstructural imaging techniques. The authors conclude that their approach provides a viable pathway for non-invasive assessment of white matter integrity.

The researchers utilize a Bayesian fitting framework combined with an optimized dual spin-echo protocol. This mechanism allows for the estimation of axon radius index by integrating structured prior information, which significantly reduces voxelwise coefficient of variation by 7-fold compared to standard approaches.

The study employs a dual spin-echo diffusion protocol. This specific sequence is chosen for its favorable eddy current properties, which are necessary for maintaining image quality and precision when performing measurements at modest gradient strengths of 35 mT m(-1).

A gradient strength of 35 mT m(-1) is necessary for this protocol. The authors demonstrate that this modest, widely-available hardware level is sufficient to obtain reproducible contrast, achieving a histogram overlap of up to 92% in healthy adult subjects.

The authors use influential priors as a data-driven component to constrain the model. This role is critical for improving the precision of radius estimates, effectively stabilizing the fitting process in the presence of noise inherent to clinical scanner hardware.

The researchers measure the axon radius index, specifically identifying sensitivity to larger fibers ranging from 3 to 15 micrometers. This measurement is validated by comparing histogram overlaps, which reach up to 92% in healthy white matter regions.

The authors propose that their method may reflect actual structural differences between white matter regions. However, they claim this interpretation requires caution because the simplified model may not fully capture the intricate complexity of biological tissue.