Related Experiment Video
Updated: Apr 12, 2026

An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
Speed-accuracy tradeoff by a control signal with balanced excitation and inhibition
Chung-Chuan Lo1, Cheng-Te Wang2, Xiao-Jing Wang3
1Institute of Systems Neuroscience, National Tsing Hua University, Hsinchu, Taiwan; Brain Research Center, National Tsing Hua University, Hsinchu, Taiwan; and.
Abstract:
A hallmark of flexible behavior is the brain's ability to dynamically adjust speed and accuracy in decision-making. Recent studies suggested that such adjustments modulate not only the decision threshold, but also the rate of evidence accumulation. However, the underlying neuronal-level mechanism of the rate change remains unclear. In this work, using a spiking neural network model of perceptual decision, we demonstrate that speed and accuracy of a decision process can be effectively adjusted by manipulating a top-down control signal with balanced excitation and inhibition [balanced synaptic input (BSI)]. Our model predicts that emphasizing accuracy over speed leads to reduced rate of ramping activity and reduced baseline activity of decision neurons, which have been observed recently at the level of single neurons recorded from behaving monkeys in speed-accuracy tradeoff tasks. Moreover, we found that an increased inhibitory component of BSI skews the decision time distribution and produces a pronounced exponential tail, which is commonly observed in human studies. Our findings suggest that BSI can serve as a top-down control mechanism to rapidly and parametrically trade between speed and accuracy, and such a cognitive control signal presents both when the subjects emphasize accuracy or speed in perceptual decisions.
More Related Videos
11:54Real-Time Proxy-Control of Re-Parameterized Peripheral Signals using a Close-Loop Interface
Published on: May 8, 2021
09:01Gain-compensation Methodology for a Sinusoidal Scan of a Galvanometer Mirror in Proportional-Integral-Differential Control Using Pre-emphasis Techniques
Published on: April 4, 2017
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Multi-input and Multi-variable systems
In the absence of...
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...