Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures
Ahmet Karakasli1, Onur Hapa2, Mehmet Erduran2
1Assistant Professor, Department of Orthopaedics and Traumatology, Dokuz Eylul University Faculty of Medicine, Izmir, Turkey.
Abstract:
For talar neck fractures, open reduction and internal fixation have been thought to facilitate revascularization and prevent osteonecrosis. Newer screw systems allow for placement of cannulated headless screws, which provide compression by virtue of a variable pitch thread. The present study compared the biomechanical fixation strength of cannulated headless variable-pitch screw fixation and locking plate fixation. A reproducible talar neck fracture was created in 14 fresh cadaver talar necks. Talar head fixation was then performed using 2 cannulated headless variable-pitch 4-mm/5-mm diameter (4/5) screws (Acutrak; Acumed, Hillsboro, OR) and locking plate fixation. Headless variable-pitch screw fixation had lower failure displacement than did locking plate fixation. No statistically significant differences were found in failure stiffness, yield stiffness (p = .655), yield load (p = .142), or ultimate load between the 2 fixation techniques. Cannulated headless variable-pitch screw fixation resulted in better failure displacement than locking plate fixation in a cadaveric talus model and could be considered a viable option for talus fracture fixation. Headless, fully threaded, variable-pitch screw fixation has inherent advantages compared with locking plate fixation, because it might cause less damage to the articular surface and can compress the fracture for improved reduction. Additionally, plate fixation can increase the risk of avascular necrosis owing to the wider incision and dissection of soft tissues.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
