Related Experiment Video
Updated: Apr 12, 2026

A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Optimal cut-off value of perfusion parameters for diagnosing prostate cancer and for assessing aggressiveness
Eunkyung Cho1, Dong Jin Chung1, Dong Myung Yeo1
1Department of Radiology, The Catholic University of Korea, Yeouido St. Mary's Hospital, 62, Yeouido-dong, Yeoungdeungpo-gu, Seoul, Korea, 150-713.
Abstract:
To determine cut-off value of dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) parameters for differentiation of prostate malignant from benign and cancer with high-grade Gleason score (GS) (GS>7) from low-grade GS (GS≤7), 35 patients (24 malignant and 11 benign) who underwent DCE-MRI were included. Difference between malignant and benign was statistically significant for all magnetic resonance parameters except Ve. The cut-off values were K(trans)=0.184min(-1), Kep=0.695min(-1), iAUC=4.219mmol/l/min, and ADC=1340.5mm(2)/s. A significant difference in mean values of K(trans) and Kep between cancer with high-grade GS and low-grade GS was also observed. K(trans) and Kep showed a significant correlation with GS.