Related Experiment Video
Updated: Apr 12, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Application of an HS-MS for the detection of ignitable liquids from fire debris
Marta Ferreiro-González1, Jesús Ayuso2, José A Álvarez2
1Department of Analytical Chemistry, Faculty of Sciences, University of Cadiz, Apartado 40, 11510 Puerto Real, Cádiz, Spain; Department of Physical Chemistry, Faculty of Sciences, University of Cadiz, Apartado 40, 11510 Puerto Real, Cádiz, Spain.
Abstract:
In arson attacks, accelerants such as ignitable liquids are commonly used to initiate or accelerate a fire. The detection of ignitable liquid residues at fire scenes is therefore a key step in fire investigations. The most widely used analytical technique for the analysis of accelerants is GC-MS. However, pre-concentration of the ignitable liquid residues is required prior to the chromatographic analysis. The standard method, ASTM E1412, involves passive headspace concentration with activated charcoal strips as a method to isolate the ignitable liquid residues from fire debris and these residues are subsequently desorbed from the carbon strip with solvents such as carbon disulfide. In the work described here, an alternative analytical technique based on an HS-MS (headspace mass spectrometry) has been developed for the thermal desorption of the carbon strips and analysis of different ignitable liquid residues in fire debris. The working conditions for the HS-MS analytical procedure were optimized using different types of fire debris (pine wood burned with gasoline and diesel). The optimized variables were desorption temperature and desorption time. The optimal conditions were 145°C and 15 min. The optimized method was applied to a set of fire debris samples. In order to simulate post burn samples several accelerants (gasoline, diesel, citronella, kerosene, paraffin, and alcohol) were used to ignite different substrates (wood, cotton, cork, paper, and paperboard). chemometric methods (cluster analysis and discriminant analysis) were applied to the total ion spectrum obtained from the MS (45-200 m/z) to discriminate between the burned samples according to the accelerant used. The method was validated by analyzing all samples by GC-MS according to the standard methods ASTM E1412 and ASTM E1618. The results obtained on using the method developed in this study were comparable to those obtained with the reference method. However, the newly developed HS-MS method is faster, safer, and more environmental friendly than the standard method.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Flame Photometry: Lab
Gas Chromatography: Types of Detectors-II
Flame Photometry: Overview
Atomic Absorption Spectroscopy: Atomization Methods
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Interference