A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Feasibility study of high-resolution DCE-MRI for glomerular filtration rate (GFR) measurement in a routine clinical
Yu-Dong Zhang1, Chen-Jiang Wu1, Jing Zhang1
1Department of Radiology, the First Affiliated Hospital with Nanjing Medical University, No. 300, Guangzhou Road, Nanjing 210000, China.
Abstract:
Dynamic contrast enhanced (DCE) MR renography has been identified as an interesting tool to determine single-kidney GFR. However, a fundamental issue for the applicability of MR-based estimate of single-kidney GFR is selecting a balance between spatial and temporal resolution of DCE-MRI data. The purpose is to assess the feasibility of GFR estimate from high-resolution (HR) dynamic contrast-enhanced (DCE) MRI in a routine clinical modal. Standard MR renography (2.4s/phase, total 4min; 4-ml Gd) and five-phase, HR-based imaging protocol (0, 30, 70, 120, and 240s; 0.05mmol/kg Gd) were prospectively performed in twelve volunteers who were scheduled for routine renal MRI. Data were plotted with Patlak, two-compartment modified Tofts model (2CTM), and two-compartment filtration model (2CFM) for GFR estimate. During all the measurements, only the signal intensities in the aorta and whole kidney parenchyma were considered. Standard 2CFM and 2CTM produced lower residuals over the fitted interval than HR-based measures (p<0.05); and HR-bases 2CFM and 2CTM did not reflect significant correlation to standard values. Standard Patlak plots with 0-240s data points produced significantly lower GFR and higher residuals than that plots with 0-120s data points (p<0.05). HR-based Patlak plots with 0, 30, 70, and 120s data points significantly correlated with reference values (Pearson ρ=0.97, p<0.01), and produced a 33.2% underestimation of reference value, which was better than that plots with 0, 30, 70, 120, and 240s data points (ρ=0.92, p<0.01; 58.6% underestimation of reference value). It concludes that it is feasible to estimate GFR with HR-based DCE-MRI and appreciate kinetic model. Patlak plots from 0, 30, 70, and 120s data points is better than plots from 0, 30, 70, 120, and 240s data points.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Imaging Studies IV: Magnetic Resonance Imaging
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...
Renal Drug Excretion: Glomerular Filtration
Drugs gain access to the kidney via the renal artery, which progressively branches off into afferent arterioles....