Improved limit of detection and quantitation development and validation procedure for quantification of zinc in
Muhammad Abdul Qadir1, Mahmood Ahmed1, Iftikharul Haq1
1Institute of Chemistry, University of Punjab, Lahore, Pakistan.
Abstract:
A simple and expeditious analytical method for determination of zinc in human insulin isophane suspension by flame atomic absorption spectrophotometer (FAAS) was validated. The method was carried out on atomic absorption spectrometer with 0.4 nm bandwidth, 1.0 filter factor on deuterium (D2) background correction. The integration time was set at 3.0 second with 5.0 mA lamp current. The parameters of method validation showed adequate linearity, efficiency and relative standard deviation values were between 0.64%-1.69% (n=7), 1.31%-1.58% (n=10) for repeatability and intermediate precision respectively. The limit of detection 0.0032 μg/mL, 0.0173 μg/mL, 0.0231 μg/mL and limit of quantitation 0.0107μg/mL, 0.0578 μg/mL, 0.0694 μg/mL based on signal to noise (SN), calibration curve method (CCM) and fortification of blank (FB) were obtained respectively. The percentages of recovery for low, medium and high spiked concentration levels of zinc in human insulin were 99.38 ± 0.04 to 100.3 ± 0.03, 98.45 ± 0.38 to 100.3 ± 0.07 and 99.42 ± 0.03 to 99.42 ± 0.08 respectively. With the use of this method, five samples from each vial of human insulin isophane suspension were analyzed and the zinc content was determined. The zinc content were 22.1 ± 0.025 μg/mL and 24.3 ± 0.028 μg/mL which compliance the British Pharmacopoeia standard.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...