Use of a 24 gauge intravenous cannula for minimally invasive trabeculectomy
Related Experiment Video
Updated: Apr 12, 2026

Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024
Tanuj Dada1, Dewang Angmo1, Shreyas Temkar1
1Glaucoma Research Facility and Cinical Services, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Abstract:
We describe an innovative technique for performing standardized low cost glaucoma filtration surgery using a polytetrafluoroethylene (PTFE) intravenous cannula. The trocar of a 24 gauge (24G) PTFE intravenous cannula was used to create a trabeculectomy ostium and its tube was inserted under a partial thickness scleral flap in 2 patients with advanced glaucomatous optic neuropathy, in whom intraocular pressure (IOP) was not controlled on maximal tolerable hypotensive therapy. Postoperatively, IOP of the operated eyes at 3, 6 and 9 months' follow-up ranged from 12 to 15 mmHg with a well formed anterior chamber and a diffuse bleb.