Photodynamic Therapy with Blended Conducting Polymer/Fullerene Nanoparticle Photosensitizers
Published on: October 28, 2015
A real-time follow-up of photodynamic therapy during PET imaging
Paté Boubacar1, Otman Sarrhini1, Roger Lecomte1
1Department of Nuclear Medicine and Radiobiology, Faculty of Medicine and Health Sciences, 3001, 12(th) Avenue North, Sherbrooke, Québec J1H 5N4, Canada.
Purpose:
To monitor a real-time follow-up of tumor response to photodynamic therapy (PDT) by dynamic 2-deoxy-2-[(18)F]fluoro-d-glucose ((18)FDG) and positron emission tomography (PET) using two photosensitizing drugs in vivo, and to assess their mechanisms of action.
Methods:
Two types of photosensitizers with different action mechanisms were used in rats implanted with two tumors: AlPcS4 mainly affecting the tumor vascular system, and ZnPcS2 largely inducing direct cell kill. Twenty-four hours after administration of either photosensitizer, one tumor served as control while the other was treated with red light during 30min within the 2h PET imaging by infusion of (18)FDG. The usual two-tissue compartment kinetic model was modified to take into account the perturbation of the treatment during imaging.
Results:
The illumination of the tumors during PET imaging provoked a net decrease of (18)FDG uptake in tumors treated with AlPcS4 and a near total absence of (18)FDG uptake in tumors treated with ZnPcS2. After the end of illumination, the tumors regained (18)FDG uptake with a more pronounced uptake in the tumors treated with ZnPcS2. The rate constant values of the new (18)FDG kinetic model reflected the response of the tumors to the treatment in both photosensitizers.
Conclusions:
Dynamic PET imaging can be used to quantitatively assess in vivo and in real-time the response of tumors to treatments. It is demonstrated that the 30min of treatment was not sufficient to reduce the activity of the tumors. The technique could be extended to directly monitor the effects of drugs in vivo.
More Related Videos
11:04An In-House-Built and Light-Emitting-Diode-Based Photodynamic Therapy Device for Enhancing Verteporfin Cytotoxicity in a 2D Cell Culture Model
Published on: January 13, 2023
10:47Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET