Related Experiment Video
Updated: Apr 12, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Electrophoretic concentration and sweeping-micellar electrokinetic chromatography analysis of cationic drugs in water
Alain Wuethrich1, Paul R Haddad1, Joselito P Quirino1
1Australian Centre for Research on Separation Science, School of Physical Sciences-Chemistry, University of Tasmania, Hobart, Tasmania 7001, Australia.
Abstract:
Sample preparation by electrophoretic concentration, followed by analysis using sweeping-micellar electrokinetic chromatography, was studied as a green and simple analytical strategy for the trace analysis of cationic drugs in water samples. Electrophoretic concentration was conducted using 50 mmol/L ammonium acetate at pH 5 as acceptor electrolyte. Electrophoretic concentration was performed at 1.0 kV for 50 min and 0.5 kV and 15 min for purified and 10-fold diluted waste water samples, respectively. Sweeping-micellar electrokinetic chromatography was with 100 mmol/L sodium phosphate at pH 2, 100 mmol/L sodium dodecyl sulfate and 27.5%-v/v acetonitrile as separation electrolyte. The separation voltage was -20 kV, UV-detection was at 200 nm, and the acidified concentrate was injected for 36 s at 1 bar (or 72% of the total capillary length, 60 cm). Both purified water and 10-fold diluted waste water exhibited a linear range of two orders of concentration magnitude. The coefficient of determination, and intra- and interday repeatability were 0.991-0.997, 2.5-6.2, and 4.4-9.7%RSD (n=6), respectively, for purified water. The values were 0.991-0.997, 3.4-7.1, and 8.7-9.8%RSD (n=6), correspondingly, for 10-fold diluted waste water. The method detection limit was in the range from 0.04-0.09 to 1.20-6.97 ng/mL for purified and undiluted waste water, respectively.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...