Related Experiment Video
Updated: Apr 12, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Ultrasound guided internal jugular venous cannulation: comparison with land-mark technique
Azmat Riaz1, Rao Ali Shan Khan1, Faisal Salim1
1Department of Anaesthesia, Combined Military Hospital, Rawalpindi.
Objective:
To compare real-time ultrasonography-guided technique versus the traditional land-mark technique for internal Jugular venous cannulation.
Study Design:
Randomized controlled trial.
Place And Duration Of Study:
Department of Anaesthesia, Combined Military Hospital, Rawalpindi, from September 2013 to July 2014.
Methodology:
A total of 200 patients who required internal jugular vein cannulation were randomly assigned using either real-time ultrasound-guided technique or land-mark technique. Access time, number of attempts until successful cannulation, complications and the demographics of each patient were recorded.
Results:
Access time was significantly less in real-time ultrasound group (34.95 ± 11.47 vs. 146.59 ± 40.20 seconds, p < 0.001). Cannulation was performed in first attempt in 99% of patients in ultrasound group as compared to 89% of landmark group. Complication rate was significantly higher in the land-mark group than in the ultrasound-guided group. Carotid artery puncture rate (9% vs. 1%) and haematoma formation (7% vs. 0%) were more frequent in the land-mark group than in the ultrasound-guided group. Brachial plexus irritation was also more in land-mark group (6% vs. 0%).
Conclusion:
Access time, failure rate and procedure related complications are reduced when real-time ultrasonography is used to cannulate internal Jugular vein.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...