Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Echo-Tracking Method Improves the Reliability in Flow-Mediated Dilation Assessment by Measuring Brachial Artery
Li-juan Du1, Wen He, Jian-hua Wang
1*Department of Ultrasound, Beijing Tiantan Hospital, Capital Medical University; and †Department of Ultrasound, The Military General Hospital of Beijing, Beijing, China.
This study found both B-mode and echo-tracking (ET) methods reliably measure flow-mediated dilation (FMD). The ET method showed improved reliability for FMD assessment, though neither technique was definitively superior.
Area of Science:
- Vascular Ultrasound
- Cardiovascular Physiology
- Medical Imaging Analysis
Background:
- Flow-mediated dilation (FMD) is a key indicator of endothelial function.
- Accurate FMD measurement is crucial for assessing cardiovascular health.
- Comparing different ultrasound techniques is essential for optimizing diagnostic accuracy.
Purpose of the Study:
- To compare intraobserver and interobserver reliability and agreement for FMD measurements using B-mode versus echo-tracking (ET) ultrasound.
- To evaluate the reproducibility of FMD assessment between two distinct ultrasound methodologies.
Main Methods:
- Twenty healthy volunteers underwent brachial artery ultrasound using both B-mode and ET methods.
- Measurements of brachial artery diameter and FMD percentage were taken by sonologists over two days.
- Intraclass correlation coefficients and Bland-Altman plots were used to assess reliability and agreement.
Main Results:
- Both B-mode and ET methods demonstrated excellent intraobserver and interobserver reliability for all assessed variables.
- Echo-tracking (ET) exhibited higher intraclass correlation coefficient values for both intraobserver and interobserver evaluations.
- Bland-Altman analysis indicated percentage differences within 18.1%–19.4% between ET and B-mode for diameter and FMD measurements.
Conclusions:
- Both B-mode and echo-tracking (ET) ultrasound methods are reproducible for assessing flow-mediated dilation (FMD).
- The ET method appears to enhance the reliability of FMD assessment compared to B-mode.
- Further research is needed to determine the optimal ultrasound method for FMD measurement.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.