Universal Route to Polycyclic Aromatic Hydrocarbon Analysis in Foodstuff: Two-Dimensional Heart-Cut Liquid
Marco Nestola1, Rainer Friedrich2, Patrick Bluhme2
1†Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstr. 5, D-45141 Essen, Germany.
Abstract:
Analysis of polycyclic aromatic hydrocarbons (PAHs) in complex foodstuff is associated with complicated and work-intensive sample preparation. Chromatographic interference has to be faced in many situations. The scope of the current work was the development of a highly efficient two-dimensional heart-cut LC-LC-GC-MS method. Detection was performed with a time-of-flight mass spectrometer (TOF-MS) to allow for a comprehensive evaluation of the obtained data in terms of cleanup efficiency. Additionally, routine detection was performed with single quadrupole MS. An easy and quick generic sample preparation protocol was realized as a first step. During method development, focus was given to optimizing HPLC cleanup for complex foodstuff. Silica-, polymeric-, and carbon-based HPLC phases were tested. Coupling of silica gel to π-electron acceptor modified silica gel showed the best cleanup properties. A four rotary valve configuration allowed the usage of a single binary HPLC pump. Screening of several fatty and nonfatty food matrices showed the absence of unwanted matrix compounds in the cleaned-up PAH fraction down to the low picogram range using TOF-MS. Limits of quantitation (LOQ) were below 0.1 μg/kg for all EU priority PAHs. Recovery rates ranged from 82 to 111%. Validation data fully complied with EU Regulation 836/2011. Sample preparation was possible in 20 min. Interlacing of HPLC and GC allowed an average method runtime of 40 min per sample.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
