Related Experiment Video
Updated: Apr 11, 2026

Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Factors affecting radiation exposure dose in nursing staff during (18)F-fluorodeoxyglucose positron emission
Kimiteru Ito1, Maki Suzuki, Aino Yamazaki
1Department of Diagnostic Radiology, Tokyo Metropolitan Geriatric Hospital.
Objectives:
We evaluated factors associated with increased radiation exposure dose in nursing staff who assisted patients with (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/computed tomography (CT) examinations.
Methods:
The Barthel Index and Mini-Mental State Examination (MMSE) score were obtained before PET/CT examinations in 193 patients (mean age ± SD, 77.7 ± 8.0 yr). Three nurses self-measured their radiation exposure dose while assisting patients during each PET examination. Disturbance factors during PET examinations (use of a stretcher or wheelchair, use of lines or tubes connected to the patient, use of diapers or urethral catheterization, patient age), (18)F-FDG injection dose, and previous PET/CT experience in the patients and outpatient or inpatient status were evaluated as factors possibly associated with increased radiation exposure. Principle component analysis, univariate analysis, and multivariate regression analysis were used for assessing associations between radiation exposure dose and factors.
Results:
The mean radiation exposure dose of the nursing staff was 6.07 ± 5.71 µSv per examination. Statistically significant factors associated with increased radiation exposure (<8 or ≥8 µSv/case) in the univariate analysis were the Barthel Index (<75 or ≥75), MMSE score (<22 or ≥22) of the patients, numbers of lines or tubes to the patient, use of a stretcher or wheelchair, and (18)F-FDG injection dose. Multivariate logistic regression modeling showed that the Barthel Index (<75 or ≥75) and MMSE score (<22 or ≥22) of the patients were significant factors in the final model.
Conclusions:
Lower Barthel Indexes (lower ADL) and lower MMSE scores (lower cognitive function) were independent factors associated with increased radiation exposure dose in nursing staff assisting during (18)F-FDG PET/CT.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Biological Effects of Radiation