Related Experiment Video
Updated: Apr 11, 2026

Author Spotlight: Advancements in Correlative Light and Electron Microscopy with Fluorescent Protein Preservation
Published on: January 12, 2024
A reference-free method for brightness compensation and contrast enhancement of micrographs of serial sections
Shi-Jie Chang1, Shuo Li2, Arne Andreasen3
1Department of Biomedical Engineering, China Medical University, Shenyang, Liaoning, China.
Abstract:
Three-dimensional (3D) reconstruction of an organ or tissue from a stack of histologic serial sections provides valuable morphological information. The procedure includes section preparation of the organ or tissue, micrographs acquisition, image registration, 3D reconstruction, and visualization. However, the brightness and contrast through the image stack may not be consistent due to imperfections in the staining procedure, which may cause difficulties in micro-structure identification using virtual sections, region segmentation, automatic target tracing, etc. In the present study, a reference-free method, Sequential Histogram Fitting Algorithm (SHFA), is therefore developed for adjusting the severe and irregular variance of brightness and contrast within the image stack. To apply the SHFA, the gray value histograms of individual images are first calculated over the entire image stack and a set of landmark gray values are chosen. Then the histograms are transformed so that there are no abrupt changes in progressing through the stack. Finally, the pixel gray values of the original images are transformed into the desired ones based on the relationship between the original and the transformed histograms. The SHFA is tested on an image stacks from mouse kidney sections stained with toluidine blue, and captured by a slide scanner. As results, the images through the entire stack reveal homogenous brightness and consistent contrast. In addition, subtle color differences in the tissue are well preserved so that the morphological details can be recognized, even in virtual sections. In conclusion, compared with the existing histogram-based methods, the present study provides a practical method suitable for compensating brightness, and improving contrast of images derived from a large number of serial sections of biological organ.
More Related Videos
11:19Multimodal Hierarchical Imaging of Serial Sections for Finding Specific Cellular Targets within Large Volumes
Published on: March 20, 2018
08:52High-resolution Episcopic Microscopy HREM - Simple and Robust Protocols for Processing and Visualizing Organic Materials
Published on: July 7, 2017
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Two-Dimensional Microscopy in Microbiology
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Overview of Electron Microscopy
Three-Dimensional Microscopy in Microbiology