[Prevalence and implicated risk factors associated with the exteriorization of cardiac pacemakers: 5 year follow-up]
Marco Argüello-Hurtado1, Milton Ernesto Guevara-Valdivia, Zulema Lisbeth Aranda-Ayala
1Departamento de Electrofisiología Cardiaca, Hospital de Especialidades, Centro Médico Nacional La Raza, Instituto Mexicano del Seguro Social, Distrito Federal. mylton@yahoo.com.
Background:
Infection is the most common complication related to permanent pacemaker implantation. The objetive of this study is to establish the prevalence and determine the frequency of risk factors associated with exteriorization of cardiac pacemakers at the Department of Cardiac Electrophysiology at the UMAE Hospital de Especialidades "Dr. Antonio Fraga Mouret" Centro Médico Nacional La Raza, Instituto Mexicano del Seguro Social.
Methods:
A descriptive cross-sectional study from September 2005 to September 2010, where, for the analysis of the risk factors we selected cases and controls by age, sex and the diagnosis of Diabetes, or not. Was calculated measures of central tendency (mean, median and mode) and chi-squared, Fisher exact test and exact odds ratio.
Results:
3192 cardiac pacemakers were implanted, identifying 83 exteriorization cases, where 46 of them were selected for cases and controls, and the mean age was 71 years.
Conclusions:
Our prevalence of exteriorization of cardiac pacemakers is 2.6 %, these results are similar to previously published studies. None of the risk factors described are present as a cause in our population. The surgical technique used may be an important risk factor, so further studies analysing all techniques are needed.
Insights
The prevalence of cardiac pacemaker exteriorization is 2.6%, with no identified risk factors in this population. Surgical technique may be a key factor, warranting further investigation into implantation methods.
Area of Science:
- Cardiology
- Medical Device Technology
- Infectious Disease Prevention
Background:
- Infection is a primary complication following permanent pacemaker implantation.
- Pacemaker exteriorization presents a significant clinical challenge.
- Understanding its prevalence and risk factors is crucial for patient care.
Purpose of the Study:
- To determine the prevalence of cardiac pacemaker exteriorization.
- To identify and analyze the frequency of risk factors associated with this complication.
- To investigate these factors within a specific tertiary care center.
Main Methods:
- A descriptive, cross-sectional study design was employed.
- Data collected from September 2005 to September 2010.
- Case-control analysis matched by age, sex, and diabetes status; statistical analysis included chi-squared and Fisher exact tests.
Main Results:
- A total of 3192 permanent pacemakers were implanted.
- 83 cases of pacemaker exteriorization were identified.
- The overall prevalence of exteriorization was 2.6%, with a mean age of 71 years in affected patients.
Conclusions:
- The study found a 2.6% prevalence of cardiac pacemaker exteriorization, consistent with prior research.
- No previously described risk factors were identified as causative in this patient cohort.
- Surgical technique emerged as a potential significant risk factor, necessitating further research into various implantation methods.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Mitral Valve Prolapse I: Introduction
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
Mitral Valve Prolapse II: Assessment and Management
Pericarditis I: Introduction