Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Diurnal Intraocular Pressure and the Relationship With Swept-Source OCT-Derived Anterior Chamber Dimensions in Angle
Laura Sanchez-Parra1, Shahina Pardhan1, Roger J Buckley1
1Vision & Eye Research Unit Postgraduate Medical Institute, Anglia Ruskin University, Cambridge, United Kingdom.
Purpose:
To evaluate diurnal intraocular pressure (DIOP) among individuals with primary angle closure (PAC) or primary angle-closure suspect (PACS). Additionally, the hypothesis that greater DIOP fluctuation is related to smaller angle parameters was investigated.
Methods:
Forty Caucasian newly referred untreated patients with bilateral PAC or PACS were recruited. Intraocular pressure (IOP) was measured hourly between 9 AM and 4 PM with Goldmann applanation tonometry. Diurnal IOP fluctuation was defined as difference between maximum and minimum IOP. Angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA), and trabecular-iris space area (TISA) were measured with anterior segment optical coherence tomography (AS-OCT) in dark (0.3-0.5 lux) and light (170-200 lux) on the same day as DIOP measurements in eight angle sections.
Results:
Intraocular pressure declined as the day progressed (P < 0.001), unrelated to presence of peripheral anterior synechiae (PAS). At each time point, eyes with PAS (n = 31) had significantly higher IOPs than eyes without PAS (n = 49; P = 0.043). Diurnal IOP fluctuation varied from 1.50 to 14.50 mm Hg (mean 5.99 mm Hg, SD 2.70 mm Hg). Diurnal IOP fluctuation was unrelated to PAS. Multiple-predictor models investigating association of angle dimensions and greater DIOP fluctuation were statistically significant for AOD 750 (light), ARA 750 (light and dark), TISA 500 (light), TISA 750 (light), TIA 500 (light), and TIA 750 (light and dark).
Conclusions:
Diurnal IOP variation has clinical implications given that IOP level is used to distinguish between diagnostic categories of PACS and PAC. Optical coherence tomography angle parameter measurements may predict for magnitude of IOP diurnal fluctuations in at-risk patients, which may be clinically useful when a clinical intervention is being considered.
More Related Videos
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
07:23Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...