Related Experiment Video
Updated: Apr 11, 2026

05:46
Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
882
The correction of electron lens aberrations.
1CEMES-CNRS, B.P. 94347, 31055 Toulouse cedex, France.
Ultramicroscopy
|May 31, 2015
Summary
This review chronicles electron lens aberration correction advancements since 1990. It highlights key publications and acknowledges pioneers in aberration corrector design and construction.
Area of Science:
- Electron optics
- Microscopy instrumentation
Background:
- Electron microscopes traditionally suffer from lens aberrations limiting resolution.
- Significant progress in aberration correction began around 1990.
Purpose of the Study:
- To chronicle the historical progress of electron lens aberration correction.
- To provide a comprehensive list of publications in this field.
- To honor key figures in aberration corrector development.
Main Methods:
- Literature review and historical analysis.
- Compilation of publication lists.
Main Results:
- Detailed account of advancements in electron lens aberration correction from 1990 onwards.
- Identification of seminal works and contributions.
Conclusions:
- The development of aberration correctors has revolutionized electron microscopy.
- Key individuals like Max Haider and Ondrej Krivanek have been instrumental in this field.
Related Concept Videos
Focusing of Light in the Eye
7.6K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
7.6K
Overview of Electron Microscopy
16.6K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
16.6K
Distance Corrections
390
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
390
Transmission Electron Microscopy
8.0K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
8.0K