Related Experiment Video
Updated: Apr 11, 2026

Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
The use of collision detection to infer multi-camera calibration quality
Sook-Yee Chong1, Beate Dorow2, Ellankavi Ramasamy2
1SimTech Research Group on Continuum Biomechanics and Mechanobiology, Institute of Applied Mechanics (CE), University of Stuttgart , Stuttgart , Germany.
Abstract:
Optical motion capture systems are widely used in sports and medicine. The performance of these systems depends on, amongst other factors, the quality of the camera calibration process. This study proposes a technique to assess the accuracy of the extrinsic camera parameters, as estimated during calibration. This method relies on the fact that solid objects in the real world cannot possess a gap in between, nor interpenetrate, when in contact with each other. In our study, we used motion capture to track successive collisions of two solid moving objects. The motion of solid objects was simulated based on trajectories measured by a multi-camera system and geometric information acquired from computed tomography. The simulations were then used to determine the amount of overlap or gap between them. This technique also takes into account errors resulting from markers moving close to one another, and better replicates actual movements during motion capture. We propose that this technique of successively colliding two solid moving objects may provide a means of measuring calibration accuracy.
More Related Videos
Related Concept Videos
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Collisions in Multiple Dimensions: Introduction
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...