Related Experiment Video
Updated: Apr 11, 2026

Modified Octopus Technique for Thoracoabdominal Aortic Aneurysm
Published on: August 1, 2025
Sheath-shunt technique for avoiding lower limb ischemia during complex endovascular aneurysm repair
Stephen C Hanley1, Simon K Neequaye2, Oren Steinmetz3
1Division of General Surgery, McGill University Health Centre, Montreal, Quebec, Canada.
A novel sheath-shunt technique maintains lower limb perfusion during complex endovascular aortic aneurysm repair, significantly reducing limb ischemia time. This method offers a safe approach to prevent complications in patients undergoing these procedures.
Area of Science:
- Vascular Surgery
- Endovascular Interventions
- Aortic Aneurysm Repair
Background:
- Endovascular repair of complex aortic aneurysms is advancing.
- A potential risk associated with these procedures is lower limb ischemia-reperfusion injury.
- Maintaining adequate blood flow to the lower extremities during repair is crucial.
Purpose of the Study:
- To introduce and evaluate a simple technique for maintaining lower limb perfusion during endovascular aortic aneurysm repair.
- To assess the efficacy and safety of the proposed sheath-shunt technique in preventing limb ischemia.
Main Methods:
- A technique involving an additional antegrade introducer sheath placed distal to the stent graft site was employed.
- This sheath was connected to the working sheath's side arm in the contralateral artery, creating a shunt.
- The technique was applied in 12 patients undergoing complex endovascular aortic aneurysm repair.
Main Results:
- The sheath-shunt technique ensured continuous pulsatile flow to the lower limb in all cases.
- Average limb perfusion flow was 42.2 ± 13.2 mL/min.
- Actual limb ischemia time was significantly reduced to an average of 14 ± 11 minutes, compared to the arterial occlusion time of 165 ± 84 minutes.
Conclusions:
- The sheath-shunt technique is a simple and effective method to maintain lower limb perfusion during complex endovascular aortic aneurysm repair.
- This technique poses minimal risk and can significantly reduce limb ischemia time.
- It is proposed as a valuable consideration for patients undergoing these complex endovascular procedures.
More Related Videos
06:26Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Aneurysm IV: Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Aneurysm III: Interprofessional Care