Related Experiment Video
Updated: Apr 11, 2026

Subcostal Specimen Removal in Completely Portal Robotic Lobectomy
Published on: April 19, 2024
Cost and Morbidity Analysis of Chest Port Insertion: Interventional Radiology Suite Versus Operating Room
Jennifer R LaRoy1, Sarah B White2, Thejus Jayakrishnan3
1Medical College of Wisconsin, Milwaukee, Wisconsin.
Insights
Chest port insertions in interventional radiology (IR) suites are significantly less expensive than in operating rooms (ORs). Complication and infection rates were similar between IR and OR procedures for chest ports.
Area of Science:
- Medical Devices
- Interventional Radiology
- Surgical Procedures
Background:
- Chest port insertion is a common procedure for long-term venous access.
- The location of chest port insertion (interventional radiology suite vs. operating room) may impact hospital costs and patient outcomes.
Purpose of the Study:
- To compare the complications and hospital costs of chest port insertions performed in an interventional radiology (IR) suite versus a surgical operating room (OR).
Main Methods:
- Retrospective review of 478 consecutive chest port placements in IR and OR settings.
- Analysis of patient demographics, complications, and infections.
- Cost analysis of 149 Medicare outpatients comparing operative and pharmacy expenses.
Main Results:
- Early complications occurred in 9.2% of IR patients vs. 13.4% of OR patients.
- Infection rates were 0.25 per 1000 catheters in IR vs. 0.18 per 1000 in OR.
- Overall mean costs were significantly higher in the OR (almost double that of IR).
Conclusions:
- Chest port insertion in an IR suite is significantly more cost-effective than in an OR.
- No significant difference in complication or infection rates was observed between the two settings.
Purpose:
To compare complications and cost, from a hospital perspective, of chest port insertions performed in an interventional radiology (IR) suite versus in surgery in an operating room (OR).
Methods:
This study was approved by an institutional review board and is HIPAA compliant. Medical records were retrospectively searched on consecutive chest port placement procedures, in the IR suite and the OR, between October 22, 2010 and February 26, 2013, to determine patients' demographic information and chest port-related complications and/or infections. A total of 478 charts were reviewed (age range: 21-85 years; 309 women, 169 men). Univariate and bivariate analyses were performed to identify risk factors associated with an increased complication rate. Cost data on 149 consecutive Medicare outpatients (100 treated in the IR suite; 49 treated in the OR) who had isolated chest port insertions between March 2012 and February 2013 were obtained for both the operative services and pharmacy. Nonparametric tests for heterogeneity were performed using the Kruskal-Wallis method.
Results:
Early complications occurred in 9.2% (22 of 239) of the IR patients versus 13.4% (32 of 239) of the OR patients. Of the 478 implanted chest ports, 9 placed in IR and 18 placed in surgery required early removal. Infections from the ports placed in IR versus the OR were 0.25 versus 0.18 infections per 1000 catheters, respectively. Overall mean costs for chest port insertion were significantly higher in the OR, for both room and pharmacy costs (P < .0001). Overall average cost to place chest ports in an OR setting was almost twice that of placement in the IR suite.
Conclusions:
Hospital costs to place a chest port were significantly lower in the IR suite than in the OR, whereas radiology and surgery patients did not show a significantly different rate of complications and/or infections.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...