Affinity Chromatography01:03

Affinity Chromatography

3.5K
Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
3.5K
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

1.4K
Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
1.4K
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

4.3K
High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
4.3K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

3.6K
High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
3.6K
Silica Gel Column Chromatography: Overview01:10

Silica Gel Column Chromatography: Overview

4.4K
Silica gel column chromatography is a technique for separating compounds using a column packed with silica gel as the stationary phase. This method relies on differences in the polarity of compounds. Based on their polarities, compounds move between the stationary phase (silica gel) and the mobile phase (the solvent), forming discrete bands in the column.
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
4.4K
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

2.0K
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
2.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Life-death trade-offs: HSV-1 ICP27 differentially modulates intrinsic apoptotic signaling in epithelial and neuron-like cells.

Frontiers in microbiology·2026
Same author

Impact of chemical structure and substituents of polysaccharide-based chiral stationary phases on cannabinoids retention under normal phase conditions.

Analytical and bioanalytical chemistry·2026
Same author

Investigation of adsorption behavior and scale up for hydroxysafflor yellow A purification from Safflower: a case study.

Journal of chromatography. A·2026
Same author

Volatilomic Differentiation of Protected-Origin Italian Balsamic Vinegars by HS-SPME-GC×GC-TOFMS.

Journal of separation science·2026
Same author

Diving into AA9-mediated transglutaminase 2 inhibition reveals ferroptosis as driver of anticancer effects.

Biochemical pharmacology·2026
Same author

Exploratory Volatilome Profiling of Inflammation in Skin Fibroblasts: A Proof-of-Concept Study.

International journal of molecular sciences·2026

Related Experiment Video

Updated: Apr 11, 2026

Author Spotlight: Optimizing Affinity Chromatography for His-Tagged FEN1 Protein
07:19

Author Spotlight: Optimizing Affinity Chromatography for His-Tagged FEN1 Protein

Published on: April 26, 2024

4.3K

Exploring Fluorous Affinity by Liquid Chromatography.

Martina Catani1, Roberta Guzzinati1,2, Nicola Marchetti1

  • 1†University of Ferrara, Department of Chemistry and Pharmaceutical Sciences, Via L. Borsari, 46, 44121 Ferrara, Italy.

Analytical Chemistry
|June 7, 2015
PubMed
Summary
This summary is machine-generated.

A single perfluorinated carbon significantly alters molecular adsorption on fluorinated surfaces, changing multilayer structures to monolayers. This finding advances understanding of fluorous affinity in chromatography.

More Related Videos

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
07:53

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study

Published on: August 16, 2019

10.0K
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.9K

Related Experiment Videos

Last Updated: Apr 11, 2026

Author Spotlight: Optimizing Affinity Chromatography for His-Tagged FEN1 Protein
07:19

Author Spotlight: Optimizing Affinity Chromatography for His-Tagged FEN1 Protein

Published on: April 26, 2024

4.3K
Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
07:53

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study

Published on: August 16, 2019

10.0K
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.9K

Area of Science:

  • Chemistry
  • Physical Chemistry
  • Materials Science

Background:

  • Highly fluorinated organic compounds exhibit unique sorption properties, termed "fluorous affinity" or "fluorophilicity."
  • Understanding the molecular basis of these properties is crucial for designing advanced materials and separation techniques.

Purpose of the Study:

  • To investigate the impact of a single perfluorinated carbon on the chromatographic behavior and adsorption properties of benzene derivatives.
  • To elucidate the role of fluorination in molecular interactions with perfluorinated stationary phases.

Main Methods:

  • Utilized nonlinear chromatography with a highly fluorinated stationary phase.
  • Studied adsorption equilibria of benzene derivatives (including α,α,α-trifluorotoluene) using acetonitrile/water eluents.

Main Results:

  • A single perfluorinated carbon atom drastically changes molecular adsorption properties on a perfluorinated stationary phase.
  • Presence of the perfluoroalkyl carbon leads to monolayer adsorption.
  • Absence of this unit results in multilayered molecular stack structures.

Conclusions:

  • Even minimal fluorination (one perfluorinated carbon) is sufficient to induce significant changes in adsorption behavior.
  • The findings provide insights into the molecular mechanisms governing fluorous affinity and fluorinated compound interactions.
  • This research aids in the rational design of chromatographic separations and understanding interfacial phenomena involving fluorinated molecules.