Related Experiment Video
Updated: Apr 11, 2026

Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
A Novel Sleep Positioning Device Reduces Gastroesophageal Reflux: A Randomized Controlled Trial
Erik Person1, Christopher Rife, Janice Freeman
1*University of Maryland Gastroenterology, Baltimore, MD †Medical University of South Carolina Gastroenterology, Charleston, SC ‡Amenity Health Inc., San Diego, CA.
Goal:
We hypothesized that sleeping left-side down with the head/torso elevated reduces recumbent gastroesophageal reflux (GER).
Background:
Previous studies show that sleeping with head of bed elevated or on wedge reduces GER and lying left-side down reduces GER versus right-side down and supine. No prior studies have evaluated the potential compounding effects of lying in an inclined position combined with lateral positioning on GER.
Study:
We evaluated a sleep-positioning device (SPD) consisting of an inclined base and body pillow that maintains lateral position while elevating the head/torso. This was a single institution, randomized controlled trial involving 20 healthy volunteers receiving 4 six-hour impedance-pH tests. After placement of reflux probe, subjects returned home, ate standardized meal, and lay down in randomly assigned positions: SPD right-side down (SPD-R), SPD left-side down (SPD-L), standard wedge any position (W), or flat any position (F). A wireless accelerometer documented position during each study. Number of reflux episodes (RE) and esophageal acid exposure (EAE) were calculated over 6 hours.
Results:
Significantly less EAE occurred during sleeping SPD-L versus sleeping W, SPD-R, and F. The most EAE occurred during sleeping SPD-R despite use of the positioning device. RE were significantly less SPD-L than SPD-R. Patients sleeping SPD-L and SPD-R spent the majority of first 2 hours and greater than half of 6 hours in assigned position. Patients sleeping W and F averaged more time supine than right or left.
Conclusions:
The sleep positioning device maintains recumbent position effectively. Lying left-side down, it reduces recumbent esophageal acid exposure.
Related Concept Videos
Gastroesophageal Reflux Disease II: Clinical Features and Management
Clinical Manifestations
GERD presents itself in a multitude of ways, with symptoms varying from person to person. The hallmark symptoms are...
Gastroesophageal Reflux Disease I: Meaning and Pathophysiology
Sleep Apnea
The condition is more prevalent among...
REM Sleep Behavior Disorder
RBD is significantly associated with...
Restless Leg Syndrome and Night Terrors
The exact cause of RLS is not fully understood, but it is believed to involve dopamine, a neurotransmitter that helps regulate muscle movement. Imbalances in dopamine levels...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...

